3Com 3CRWEASYA73 User Manual page 166

3com outdoor 11a building to building bridge and 11bg access point
Hide thumbs Also See for 3CRWEASYA73:
Table of Contents

Advertisement

C
6: C
L
HAPTER
OMMAND
INE
Syntax
Default Setting
Command Mode
Command Usage
Example
Outdoor 11a Building to Building(config)#snmp-server targets mytraps
Outdoor 11a Building to Building(config)#
snmp-server filter
This command configures SNMP v3 notification filters. Use the no form to delete
an SNMP v3 filter or remove a subtree from a filter.
I
NTERFACE
snmp-server targets <target-id> <ip-addr> <sec-name>
[version {3}] [udp-port {port-number}] [notification-type
{TRAP}]
no snmp-server targets <target-id>
• target-id - A user-defined name that identifies a receiver of SNMP
notifications. (Maximum length: 32 characters)
• ip-addr - Specifies the IP address of the management station to receive
notifications.
• sec-name - The defined SNMP v3 user name that is to receive
notifications.
• version - The SNMP version of notifications. Currently only version 3 is
supported in this command.
• udp-port - The UDP port that is used on the receiving management
station for notifications.
• notification-type - The type of notification that is sent. Currently only
TRAP is supported.
None
Global Configuration
• The access point supports up to 10 SNMP v3 target IDs.
• The SNMP v3 user name that is specified in the target must first be
configured using the snmp-server user command.
192.254.2.33 chris