1. Turn the unit off and allow it to cool down to room temperature.
2. Shut off the gas and power supply to the unit.
3. Remove the faceplate or door frame -see instruction in this manual.
4. Remove the mesh barrier (see instructions in manual) and glass door.
a) Remove the 3 screws shown below at the bottom of the glass
.
door
b) Swing the door out 45
o
5. Remove the inner panels - reverse of "Inner panel Installation" in this
manual.
6. Remove the burner tray cover by lifting up and out as shown below.
* Prior to removing burner - remove crystals, pebbles, spa stones and inner
panels - if installed.
7. Remove 3 screws on the burner to release it - locations shown below.

VALVE ASSEMBLY REPLACEMENT

from the bottom and lift up and out.
8. Remove the burner by sliding it to the right - then lift out.
9. Remove the valve access plate by undoing the 8 screws - see locations
below.
10. Disconnect the inlet gas line and remove the valve assembly.
11. Replace valve assembly and reverse steps.