The diagrams below shows examples of horizontal termination arrangements using one, two, or three 90
1. A maximum of three 90
elbows are permitted (not including the starting 45
o
2. Minimum distance between elbows is 1 ft. (305mm).
Maintain clearances to combustibles as listed in the "Clearances" section.
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing through a wall.
Must use optional rigid pipe adaptor (Part# 510-994. when using rigid pipe vent systems.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
26 |
Regency Horizon™ HZ40E-10 Gas Fireplace
HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6-5/8
Straight Out Horizontal Venting
Diagram 1
center
of hole
C L
Please note the minimum centerline for
basic install shown above.
"
elbows (two 45
o
elbow at the flue collar when using rigid venting).
o
C L
elbows equal one 90
elbow)
o
o