Horizontal Terminations Flex Vent 4" X 6-7/8 - Regency Fireplace Products Horizon HZ40E-NG10 Owners And Installation Manual

Hide thumbs Also See for Horizon HZ40E-NG10:
Table of Contents

Advertisement

installation
|
24
These venting systems, in combination with the HZ40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock
Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination
Locations" section.
Regency
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the HZ40E using a flexible vent.
®
FPI Kit #
Length
Contains:
#946-513
2 Feet
1.
2.
3.
4.
#946-515
4 Feet
5.
6.
7.
8.
#946-516
10 Feet
9.
Notes:
1. Liner sections should be continuous without any
joints or seams.
2. Only Flex pipe purchased from Regency
used for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Regency
Direct Vent System (Flex) is only approved
®
for horizontal terminations.
5. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer
runs are required, rigid pipe must be used.
24 |
Regency Horizon™ HZ40E-10 Gas Fireplace
HORIZONTAL TERMINATIONS
6-7/8" flexible outer liner (Kit length)
4" flexible inner liner (Kit length)
spring spacers
thimble
AstroCap termination cap
screws
tube of Mill Pac
plated screws
S.S. screws #8 x 1-1/2" drill point
may be
®
"
FLEX VENT 4" X 6-7/8
Vent Guard
(Part #946-506/P)