Regency Fireplace Products Classic H2100M Owners & Installation Manual

Wood fireplace insert & hearth heater

Advertisement

Quick Links

Classic
H2100M & I3100L
Wood
Fireplace Insert &
Hearth Heater
Owners & Installation Manual
www.regency-fire.com
MODELS:
H2100M
I3100L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-548
12.02.15

Advertisement

Table of Contents
loading

Summary of Contents for Regency Fireplace Products Classic H2100M

  • Page 1 Classic ™ H2100M & I3100L Wood Fireplace Insert & Hearth Heater Owners & Installation Manual www.regency-fire.com MODELS: H2100M I3100L Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.
  • Page 2 Thank-you for purchasing a REGENCY PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. “This wood heater has a manufacturer set minimum low burn rate that must not be altered.
  • Page 3: Table Of Contents

    table of contents SAFETY LABEL OPERATING INSTRUCTIONS Safety Label For I3100l ..........4 Seasoned Wood ............16 Safety Label For H2100M..........5 First Fire ..............17 Fan Operation (All Units) ..........17 UNIT DIMENSIONS Ash Disposal..............17 Some Safety Guidelines ..........17 Unit Dimensions For I3100L ..........6 Creosote ..............18 Unit Dimensions For H2100M ........7 MAINTENANCE...
  • Page 4: Safety Label For I3100L

    safety decal This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Large Flush Insert. We have printed improved. Check the label on the unit and if a copy of the contents here for your review. there is a difference, the label on the unit is the correct one.
  • Page 5: Safety Label For H2100M

    safety decal This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Hearth Heater. We have printed a improved. Check the label on the unit and if copy of the contents here for your review. there is a difference, the label on the unit is the correct one.
  • Page 6: Unit Dimensions For I3100L

    safety decal UNIT DIMENSIONS FOR I3100L (27-1/2”) (699mm) (26”) (660mm) (Collar) (6”) (15-13/16”) (152mm) (402mm) (1-7/16”) (36mm) (6-7/8”) (10-3/8”) (175mm) (263mm) (37-1/2”) (952mm) (9-7/16”) (4-15/16”) (6-1/4”) (44”)* (240mm) (125mm) (159mm) (1118mm) (32”)* (813mm) (23-1/4”) (22-7/8”) (590mm) (581mm) (5-1/2”) * Regular Faceplate (140mm) Oversize Faceplate is 50”...
  • Page 7: Unit Dimensions For H2100M

    safety decal UNIT DIMENSIONS FOR H2100M (28”) (711mm) (24-5/8”) (625mm) (6”) (1-5/16”) (152mm) (33mm) (19-13/16”) (503mm) (3-3/8”) (2-1/8”) (7”) (86mm) (178mm) (54mm) (20”) (22-1/2”) (20-3/8”) (508mm) (571mm) (517mm) (28” with legs) (16-13/16”) (711mm) (427mm) (16-1/8”) (25-7/16”) (409mm) (646mm) (5”) (127mm) Regular faceplate is 40 1/4 W x 30”...
  • Page 8: Installation

    installation CHIMNEY Regency Inserts are constructed with the high- 9) Inserts that project in front of the fireplace est quality materials and assembled under strict must be supplied with appropriate supporting SPECIFICATIONS quality control procedures that insure years of means. trouble free and reliable performance.
  • Page 9: Optional Flue Connector Kit

    installation OPTIONAL FLUE Position the grill on the inside bodyface side and fasten using the bolts, washers and nuts provided CONNECTOR KIT (2 per side) as shown in the diagrams. The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your flue connector and the insert collar.
  • Page 10: Leg Option On H2100 Hearth Heater

    installation LEG OPTION ON H2100 INSTALLATION INTO A In Canada this fireplace insert must be installed with a continuous chimney liner HEARTH HEATER MASONRY FIREPLACE of either 5.5" or 6" diameter extending from the fireplace insert to the top of the The addition of legs to the Hearth Heater does chimney.
  • Page 11: Faceplate And Trim

    installation FACEPLATE AND TRIM B) All units 4) If the floor of your fireplace is below the level of the fireplace opening, adjust the The unit may now be slid into final position and insert's levelling bolts to accommodate the Prior to sliding your insert into its final position attached to the connection system.
  • Page 12: Fan / Blower

    installation FAN / BLOWER Installer: Please record unit serial number here before installing blower. Serial No.______________________________ Your fan should only be installed once the unit is 3) Ensure that the power cord is not in contact CAUTION: Label all wires prior in place in order to prevent any damage to the with any hot stove surfaces.
  • Page 13: Floor Protection

    installation FLOOR PROTECTION BRICK FLUE BAFFLE & SECONDARY AIR TUBE Please check to ensure that your floor protection and hearth will meet the standards for clearance INSTALLATION to combustibles. Your hearth extension must be made from a non-combustible material. The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier.
  • Page 14: Stainless Steel Smoke Deflector Adjustment /Replacement

    installation STAINLESS STEEL SMOKE DEFLECTOR ADJUSTMENT / REPLACEMENT The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening.
  • Page 15: Draft Control

    installation SCREEN DOOR Hearth Heater (H2100M) Slide the rear of the baffle on top of the rear (I3100 ONLY) air channel in front of the locating tabs. Make Steel Baffle sure that the insulation is lying flat and does Hook screen to the inside on the right side not obstruct the smoke from getting up the flue Place the insulation batt on top of the baffle.
  • Page 16: Operating Instructions

    operating instructions SEASONED WOOD Whether you burn wood in a fireplace, stove or insert, good quality firewood is the key to convenience, efficiency and safety. Wet wood and pieces that are not the right size and shape for your wood burner can be frustrating, burn inefficiently and deposit creosote that can fuel a dangerous chimney fire. Good planning, seasoning and storage of the firewood supply are essential to successful wood burning.
  • Page 17: First Fire

    operating instructions 10) For those units installed at higher elevations How to Light & Maintain a Wood Stove Fire matic temperature sensor will engage the blower FIRST FIRE or into sub-standard masonry fireplaces, when the unit is at temperature and will shut off drafting problems may occur.
  • Page 18: Creosote

    maintenance DOOR LATCH 7) Your Regency Insert can be very hot. You has been done. In the event that removal is re- may be seriously burned if you touch the quired, be sure not to damage any parts needed ADJUSTMENT insert while it is operating.
  • Page 19 maintenance Annual Maintenance Completely clean out entire unit Annually Inspect air tubes, baffles and bricks Replace any damaged parts. Adjust door catch / latch If unable to obtain a tight seal on the door - replace door gasket seal. Readjust latch after new gasket installed. Inspect condition and seal of: Glass Gasket Door Gasket...
  • Page 20: Parts List

    parts list I3100 MAIN ASSEMBLY Part # Description 850-151 Door Assembly - Large Black (I3100) 850-153 Door Assembly - Large Nickel Accent (I3100) 846-304 Glass - Replacement - (I3100) 936-243 7/8" Adhesive Tape Gasket 846-920 Glass Retainer Clips/Screws (set of 8) Screw 1/4-20 x 3/8"...
  • Page 21: I3100 Faceplates

    parts list I3100 FACEPLATES Part # Description Faceplate: I3100L 163-910 Faceplate & Trim Set - Regular 163-570 Black Trim Regular (Set of 3) 385) * Trim Right Regular 386) * Trim Top Regular 387) * Trim Left Regular 388) * Faceplate Side Regular 389) * Faceplate Top Regular...
  • Page 22: H2100 Main Assembly

    parts list H2100 MAIN ASSEMBLY Part # Description Part # Description 39) 120-950 Steel Baffle 850-151 Door Assembly - Large Black 948-223 Regency Logo 850-153 Door Assembly - Large Nickel Accent Faceplate: H2100M 846-304 Glass - Replacement 120-910 Faceplate & Trim Set - Regular 936-243 7/8"...
  • Page 23: I3100 & H2100 Firebrick

    parts list I3100 & H2100 FIREBRICK Part # Description 120-960 H2100 Brick Set Complete 163-960 I3100 Brick Set Complete 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) * Brick Partial: 1-1/4" x 4" x 9" 72) * Brick Partial: 1-1/4"...
  • Page 24 notes 24 | Regency Wood Insert & Hearth Heater...
  • Page 25 notes Regency Wood Insert & Hearth Heater...
  • Page 26 notes 26 | Regency Wood Insert & Hearth Heater...
  • Page 27: Warranty

    Wood Stoves and Inserts Warranty 2015 Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thorough- ly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 28 Register your Regency warranty online ® www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Classic i3100l

Table of Contents