Vertical Termination With Co-Linear Flex System - Regency Fireplace Products Horizon HZ40E-NG10 Owners And Installation Manual

Hide thumbs Also See for Horizon HZ40E-NG10:
Table of Contents

Advertisement

THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERV-
ING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. See the "Venting
Arrangements - Vertical Terminations" Section for
minimum and maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Rigid Pipe Adaptor
46DVA-E45 45
Elbow
o
Alternate Approved Caps
46DVA-VC
Vertical Termination Cap
46DVA-VCH High Wind Cap
46DVA-GK
3" Co-linear Adapter with flashing
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM
Masonry chimneys may take various contours which the flexible liner will accommodate. However,
keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
with Kit#
946-563
Pipe Length
Rigid Pipe Adapter
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
of two certified
joiner kits
may be used
per length.
#948-305
35 ft (11m)
Exhaust
Flue
Outer
Pipe
o
45 Elbow
Inner Pipe
Adapter
with Kit#
946-563
Regency Horizon™ HZ40E-10 Gas Fireplace
installation
|
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563
31
|
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz40e-lp10Horizon hz40e-ng1

Table of Contents