11. Install the fan control module (FCM) into the bracket on the side access
panel. Plug in the power cord to the outlet in the unit. Reinstall the panel
with the 4 screws from step 10.
12. Plug in the fan power cord to the Fan Control Module into the outlet
marked "Fan". Plug the FCM-COM wire from the remote control wiring
harness into the location on the Fan Control Module marked "COM".
Turn the switch on the Fan Control Module to the ON position. ON is to
the left. The "O" is the off position
919-405
TO REMOVE THE FAN
1. Turn the power off.
2. Reverse the above instructions.
Maintenance: The sealed bearings are lubricated, there is no need to lu-
bricate them further. (Extra lubricant will cause more lint and dust buildup
- causing the bearings to prematurely fail).
Regular cleaning and vacuuming of the fan area will add to the life of the
motor.
FCM-COM connector
2
IMPORTANT:
These fans collect a lot of dust from within your home. Ensure you
maintain these fan motors on a regular basis by vacuuming
the fan blades and housing using a soft brush nozzle.