E-TON EV3 E-MO Service Manual page 62

Table of Contents

Advertisement

CHECKING THE BULBS AND BULB SOCKETS
2. Check:
• bulb (for continuity)
(with the pocket tester)
No continuity
TIP
Before checking for continuity, set the pocket
tester to "0" and to the "
a. Connect the positive tester probe to termi-
nal
and the negative tester probe to ter-
1
minal
, and check the continuity.
2
b. Connect the positive tester probe to termi-
nal
and the negative tester probe to ter-
1
minal
, and check the continuity.
3
c. If either of the readings indicate no conti-
nuity, replace the bulb.
CHECKING THE CONDITION OF THE BULB
SOCKETS
The following procedure applies to all of the
bulb sockets.
1. Check:
• bulb socket (for continuity)
(with the pocket tester)
No continuity
TIP
Check each bulb socket for continuity in the
same manner as described in the bulb section;
however, note the following.
a. Install a good bulb into the bulb socket.
b. Connect the pocket tester probes to the
respective leads of the bulb socket.
c. Check the bulb socket for continuity. If any
of the readings indicate no continuity, repla-
ce the bulb socket.
6-6
ELEC
Replace.
x 1" range.
Replace.
+