Datamax H Class Operator's Manual page 74

Hide thumbs Also See for H Class:
Table of Contents

Advertisement

Communications
Within the Communications branch, the following menu selections are available:
Serial Port A
Serial Port C
Serial Port D
Parallel Port A
NIC Adapter
Host Settings
The menu selections are defined as follows:
DISPLAYED ITEM ITEM DESCRIPTION
SERIAL PORT A
BAUD RATE
1200 BPS
2400 BPS
4800 BPS
9600 BPS
19200 BPS
28800 BPS
38400 BPS
57600 BPS
115000 BPS
PROTOCOL
BOTH
SOFTWARE
HARDWARE
NONE
PARITY
NONE
ODD
EVEN
DATA BITS
7
8
STOP BITS
1
2
Controls the RS-232 communications settings for Serial Port A, as
follows:
Sets the serial communication rate:
1200 bits per second
2400 bits per second
4800 bits per second
9600 bits per second (Default Setting)
19200 bits per second
28800 bits per second
38400 bits per second
57600 bits per second
115000 bits per second
Sets the data flow control (handshaking) method, where:
XON/XOFF and CTS/DTR are used. (Default Setting)
XON/XOFF is used.
CTS/DTR is used.
Flow control is not used.
Sets word parity, where:
Parity is not used. (Default Setting)
Odd parity is used.
Even parity is used.
Sets word length, where:
A seven bit word is used.
An eight bit word is used. (Default Setting)
Sets the number of stop bits, where:
One stop bit is used. (Default Setting)
Two stop bits are used.
66