REDUNDANCY
Ensures integrity by setting the number of consecutive, identical decodes that are
LEVEL *
required for the bar code to be considered readable. For example, if set to three
times, the bar code will not pass until the same values have been decoded three
times in succession.
The setting range is 1 – 6, and Auto.
Notes: (1) Depending upon the print speed, higher verification levels may
2
Is the Default Setting.
SET DEFAULTS
Resets the Scanner to the default values, as follows:
*
RFID
Controls the programming and verification of RFID tags, where:
RFID MODULE
Sets the mode of RFID operation:
Note: If trying to enable RFID operation without option's presence (installed or
DISABLED
Disables the option.
HF
Selects the High Frequency RFID option.
UHF MULTI-
Selects the Ultra-High Frequency RFID option.
PROTOCOL
RFID POSITION
(1.10 - 4.00 INCHES)
*
1.10
Is the Default Setting.
HF SETTINGS *
Sets HF tag parameters:
TAG TYPE
Sets the tag type:
AFI VALUE
(00 - FF)
AFI LOCK
ENABLED / DISABLED
DSFID VALUE
(00 - FF)
DSFID LOCK
ENABLED / DISABLED
EAS VALUE
(00 - FF)
AUDIO
ENABLED / DISABLED
INDICATOR
ERASE ON
ENABLED / DISABLED
FAULT
cause erroneous failures when scanning multiple bar codes or bar
codes that are small in height.
(2) When 'Auto' is selected, the printer defaults to a MIN READABLE
HEIGHT setting of 1/16.
Mode = Auto
Barcode Count = 00
Min Readable Height = Disabled
Redundancy Level = 2
detected), the printer will initially respond with a DISABLED message.
ISO 15693
TI
PHILIPS
ST LRI512
ST LRI64
52