PROCESS
Selects from the list of external extensions and, as noted, converts then stores them
FILE *
with internal file extensions.
External
Extension
BMP, PCX,
IMG, & F7B
SFL & SFP
FORMAT
Selects from a list of modules (D, F, G, H, X, and Y ) available for formatting.
MODULE *
To use an external memory device (SDIO or Thumbdrive), it must first be formatted
by the printer. During this formatting process, a folder (labeled F or H, respectively)
will be made in the module. All formats to be used by the printer must be placed
within this folder to be recognized.
DELETE FILE
Selects from the list of available files for deleting. (Protected modules will not appear
*
in this list.)
COPY FILE * Selects from the list of available files for copying and then prompts you for the
destination module before execution.
Converts the file into an internal format, where
the result is stored in Module G.
BS
Upgrades the printer boot-loader.
DPL
Parses file, and if label format then prints a
label.
LS
Converts the file into an internal format, where
the result is stored in Module Y.
PLG
Converts the file into an internal format, where
the result is stored as specified in the PLG file
(typically Module X).
Converts file into an internal format. The last
three characters of the name should
correspond to the Font ID. (If the filename
does not contain a Font ID, you will be
prompted to enter it.) The resulting file is
stored in Module G.
TTF
Converts the file into internal format. Last two
characters of the name should correspond to
the Font ID. (If the filename does not contain
a Font ID, you will be prompted to enter it.)
The resulting file is stored in Module G.
ZS
Upgrades the printer firmware.
Choosing FORMAT MODULE will erase existing data in the selected
module.
Action
50
Converted
(Internal)
Extension
DIM
N/A
N/A
DLN
PLU
DBM
DTT
N/A