LABEL LENGTH
Determines the length of the label (0 - 99.99 inches) when the SENSOR TYPE is
set to CONTINUOUS, where:
04.00 inches
Is the Default Setting.
MAXIMUM
Sets the length of media (0 - 99.99 inches) that the printer will attempt to feed
LABEL LENGTH
between the sensing of TOF gaps or marks (when the Sensor Type is set to GAP
or REFLECTIVE) before a TOF Fault is declared, where:
16.00 inches
Is the Default Setting.
Note: It is recommended that Maximum Label Length be at least 2.5 to 3 times the physical length
of the label.
PAPER EMPTY
Sets the length of media (0 - 99.99 inches) the printer will attempt to feed before
DISTANCE
an Out Of Stock Fault is declared. This setting should be set longer then the
actual label size when using clear or translucent media, where:
00.25 inches
Is the Default Setting.
LABEL WIDTH
Sets the maximum printable width (0.75 - 4.10 inches). Objects extending beyond
this setting will NOT print, where:
4.10 inches
Is the Default Setting.
RIBBON LOW
Define the printer response when THERMAL TRANSFER mode is selected and
OPTIONS
the ribbon supply begins to diminish.
RIBBON LOW
Sets the threshold diameter (1.00 - 2.00 inches) of the depleted ribbon supply that
DIAMETER
will trigger a Low Ribbon Warning prompt, where:
1.38 inches
Is the Default Setting.
PAUSE ON
Allows the printer to enter a paused condition when the Ribbon Low Diameter
RIBBON LOW
threshold is exceeded, where:
ENABLE
Sets the printer to pause when a Ribbon Low Diameter condition is detected; the
PAUSE Key must be pressed to proceed with the print job.
DISABLE
No action is required by the operator; printing can continue until a Ribbon Fault is
declared.
SENSOR
Selects the method used to adjust the printer to sense media, where:
CALIBRATION
PERFORM
Sets the values for media sensing via internal printer calculations, as described in
CALIBRATION
the STANDARD CALIBRATION procedure.
ADVANCED
Sets the media sensor values via manual entry (typically for custom or hard to
calibrate label stocks), as described in the ADVANCED ENTRY CALIBRATION
ENTRY
where:
PAPER
Establishes the threshold for the paper value (0 - 255), where 170 is the Default
SENSOR
Setting.
LEVEL
REFL PAPER
Establishes the threshold for the reflective value (0 - 255), where 170 is the
LEVEL
Default Setting.
GAP SENSOR
Establishes the threshold for the gap value (0 - 255), where 040 is the Default
LEVEL
Setting.
MARK SENSOR
Establishes the threshold for the mark value (0 - 255), where 040 is the Default
LEVEL
Setting.