TERMINAL AND CONNECTOR REPAIR–HOW TO INSTALL AND REMOVE SPECIAL CONNECTORS
Locking Arm
1.
Cut the connection of the connector
(1)
Hold back
rib to pull
connector
(2)
NOTICE:
Do not hold the wire harness to pull it.
2.
Connect the Connector
(1)
back ribs
(2)
Wire Harness Repair Manual (RM1022E)
Push down on locking arm to unlock. Then hold the
back ribs of connector to remove connector.
Cut the Connection of the connector.
Align the direction of locking feature in same direction
and mate the connector holding the back ribs in
straight direction.
Insert it until a lock securely locks, and pull the
connector lightly after the insertion, and confirm that
a lock is enabled.
B–53