3.6 IMAGE TRANSFER

3.6.1 IMAGE TRANSFER BELT UNIT

To simplify the procedure, remove the lower fusing entrance guide instead of the fusing unit
during image transfer belt removal.
1.
Remove all the AIO cartridges (
2.
Transfer unit (
Lower Fusing Entrance Guide
3.
Remove the lower fusing entrance guide (1 hook).
4.
Remove the waste toner bottle.
5.
Remove the two screws [A].