Service Menu (MF Model)
Flatbed Main
Reg.
Flatbed Sub
Reg.
ADF Main Reg.
ADF Sub Reg.
Size Adjust
Flatbed Main
Reg.
Flatbed Sub
Reg.
Fax Maintenance (G181 doesn't support this.)
RX Level
Modem Settings
TX Level
G165/G166/G167/G181/G183/G184
CÓPIA NÃO CONTROLADA
Adjusts the Flatbed Scan main-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the Flatbed Scan sub-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan main-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan magnification.
(G181 doesn't support this.)
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Sets the reception level.
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Sets the transmission level.
[0 dBm/ -1 dBm/ -2 dBm/ -3 dBm/ -4 dBm
/ -5 dBm/ -6 dBm/ -7 dBm/ -8 dBm/ -9 dBm
/ -10 dBm/ -11 dBm/ -12 dBm/ -13 dBm
/ -14 dBm/ -15 dBm]
5-42
CÓPIA NÃO CONTROLADA
SM