Timeout Length
BT Setting
BT Frequency
BT (Busy Tone)
Detection
BT Level
BT Cadence
RTN Rate
Comm Settings
V34 Modem
V17 Modem
G165/G166/G167/G181/G183/G184
CÓPIA NÃO CONTROLADA
This setting sets the time-out length for the 1st dial
tone detection. The machine waits for a dial tone
for the specified time and disconnects itself from
the line when no dial tone is input.
[10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec]
DFU
[Off/ On]
BT: Busy tone
DFU
[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550
Hz/ 350-500 Hz/ 350-550 Hz/ 375-475 Hz/
380-520 Hz]
DFU
[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB]
DFU
[0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50/
0.75]
The machine checks the actual data
reconstruction errors and then transmits an RTN
depending on the decoding error rate that is set by
this setting (Number of lines containing an error
per page / Total number of lines per page).
[10%/ 15%]
DFU
[Permitted (Default)/ Prohibited]
DFU
[Permitted (Default)/ Prohibited]