Service Menu (MF Model)
00* – 7F
Brand ID
Displays the current brand ID number.
Do not change this setting (Designed for Factory Use).
00* – 7F
Maintenance ID
Displays the current maintenance ID number.
Do not change this setting (Designed for Factory Use).
Input 160 bytes
LSU Adjustment
setting.
When you execute "Trans. Belt Adjust", the transfer belt adjustment is
Trans. Belt Adjust
done. This calibrates the motor speed to match the length of the new
transfer belt.
Fuser SC Detect
On/Off*
Color
The engine will do color registration and density tuning automatically.
Registration
The printer will warm up automatically after this setting is changed.
Reset Transfer
Resets the transfer unit life counter.
Unit Life Counter
Fuser SC Reset
This button is for resetting an SC related with the fusing errors.
G165/G166/G167/G181/G183/G184
CÓPIA NÃO CONTROLADA
Character: alphanumeric "0-9", "a-f", "A-F", only
valid data can be input.
Input length: 160 bytes
If On, the engine detects SC559. If Off, the engine
does not detect "Fusing SC Reset."
5-38
CÓPIA NÃO CONTROLADA
SM