6. The default notification sends only the event when it occurs.
Note that you can also modify the Information to Send field to forward profile data or
support data, either when an event occurs or at regular intervals. Make use of this feature
whenever possible, as shown in Figure 4-93.
Figure 4-93 E-mail notification setup
Be aware that sending the support data at regular frequencies might impact the capacity
of the destination e-mail address box.
Note: Besides the e-mail notification with error capture attached, there is another
option to collect diagnostic data when an error is detected, that is, by enabling
automatic collection of support data. See "Gathering support information" on page 231
for more information.
7. When you have finished adding e-mail addresses to notify, test your specified SMTP and
e-mail addresses by clicking the Test button.
8. If you have a Network Management Station (NMS) in your network collecting traps, select
the SNMP tab to define the settings for SNMP alerts. Type the IP address of your SNMP
console and the community name. As with the e-mail addresses, you can define several
trap destinations.
226
IBM Midrange System Storage Hardware Guide