IBM Midrange System DS4000 Series Hardware Manual page 240

Midrange system storage ds4000/ds5000 series
Hide thumbs Also See for Midrange System DS4000 Series:
Table of Contents

Advertisement

The disks drives are shown as Offline. To start using one, right-click it, select Online, and
then Initialize. After that, click the Unallocated space to partition the disk and assign a drive
letter.
Storage Manager provides another utility to display the logical drives mapped. You can
access this utility by opening your Storage Manager installation directory and run the
SMdevices utility from a command prompt. Once you run the utility, you will see the output
shown in Example 4-1.
Example 4-1 SMdevices output
C:\Program Files\IBM_DS\util>SMdevices
DS Storage Manager Utilities Version 10.01.35.01
Built Fri Jun 19 06:12:18 CDT 2009
IBM System Storage DS Storage Manager(Enterprise Management)
(C) Copyright International Business Machines Corporation, 2003-2009 Licensed Ma
terial - Program Property of IBM.
All rights reserved.
US Government Users Restricted Rights - Use, Duplication, or disclosure restrict
ed by GSA ADP Schedule Contract with IBM Corp.
IBM Support URL=http://www.ibm.com/servers/storage/support/disk/
\\.\PHYSICALDRIVE1 [Storage Subsystem DS5020, Logical Drive LogDrive1, LUN 0,
Logical Drive ID <60080e500017b53e000048364a9fb470>, Preferred Path (Controller-
A): In Use]
\\.\PHYSICALDRIVE2 [Storage Subsystem DS5020, Logical Drive LogDrive2, LUN 1,
Logical Drive ID <60080e500017b5bc000044e34a9fb474>, Preferred Path (Controller-
B): In Use]
\\.\SYMsmUTMLun0 [Storage Subsystem DS5020, Logical Drive Access, LUN 31, Logi
cal Drive ID <60080e500017b5bc000043834a955f8a>]
\\.\SYMsmUTMLun1 [Storage Subsystem DS5020, Logical Drive Access, LUN 31, Logi
cal Drive ID <60080e500017b5bc000043834a955f8a>]
Note that so far we updated the storage system to the latest level, configured logical drives,
set up storage partitioning, and configured you host system. The next step is to define the
alerting methods to be used in case of failures.
For more information about drive mapping in other operating systems, see IBM Midrange
System Storage Implementation and Best Practices Guide, SG24-6363.
222
IBM Midrange System Storage Hardware Guide

Advertisement