IBM Midrange System DS4000 Series Hardware Manual page 137

Midrange system storage ds4000/ds5000 series
Hide thumbs Also See for Midrange System DS4000 Series:
Table of Contents

Advertisement

If you are connected to a hub or switch, check the Name Server Table of the hub or switch to
identify the WWN of the HBAs.
For iSCSI attachment, you need to know the host port identifier, or iSCSI initiator name of the
cards running iSCSI protocol. The iSCSI initiator can be implemented by specific host bus
adapter hardware called
connectivity through an Ethernet network interface card (NIC). iSCSI names, as the WWPN in
FC, have a global scope, are independent of address or location, and are persistent and
globally unique. Names must be extensible and scalable with the use of naming authorities.
Changing this name might cause conflicts within the system. The standard supported for the
DS5000 reading iSCSi naming convention is the or iSCSI qualified name (IQN) standard.
When planning your partitioning, keep in mind that:
In a cluster environment, you need to use host groups.
You can optionally purchase partitions up to the limit of the specific DS model.
A given partition should not contain hosts that are FC-based as well as hosts that are
iSCSI-based.
A single host should not be configured for both iSCSI connections and FC connections to
the storage system.
When planning for your storage partitioning, you should create a table of planned partitions
and groups so that you can clearly map out and define your environment.
Best practice: If you have a single server in a host group that has one or more LUNs
assigned to it, we recommend that you do the mapping to the host and not the host group.
All servers having the same host type (for example, Windows servers) can be in the same
group if you want, but by mapping the storage at the host level, you can define what
specific server accesses which specific LUN.
However, if you have a cluster, it is good practice to assign the LUNs at the host group, so
that all of the servers on the host group have access to all the LUNs.
Table 4-4 shows an example of a storage partitioning plan. This clearly shows the host
groups, hosts, port names, WWN of the ports, and the operating systems used in that
environment. Other columns can be added to the table for future references, such as HBA
BIOS levels, driver revisions, and switch ports used, all of which can then form the basis of a
change control log.
Table 4-4 Sample plan for storage partitioning
Host group
Host name
Windows 2008
Mail
Linux
Lin_Host
System p
AIX1
iSCSI
TSM
Windows
a. *IQN or iSCSI qualified name
iSCSI cards
, or by software that runs on the host and provides
Port alias
Host port ID
MailAdp_A
200000E08B28773C
MailAdp_B
200000E08B08773C
LinAdp_A
200100E08B27986D
LinAdp_B
200000E08B07986D
AIX1Adp_A
20000000C926B6D2
AIX1Adp_B
20000000C926B08
TSM_iP0
iSCSI IP + IQN
TSM_iP1
iSCSI IP + IQN
Chapter 4. IBM System Storage DS planning and configuration
OS type
Windows 2008
Non-Clustered
Linux
AIX
a
Windows 2008
Non-Clustered
a
119

Advertisement

Table of Contents
loading

Table of Contents