4.3 Error Codes
Table 4-20 WOW Motion Control Processor (MCP) Error Codes (2Axx)
Error
Description
2A3E
WOW Weighing Error. While weighing a mail piece the WOW MCP reports an error.
2A3F
Width sensor calibration error at start of run.
2A8E
WOW unable to weigh – weight unstable.
2AAC
WOW Error. General-purpose error reported by the WOW MCP.
2AAD
Weight Break Download Sequence error.
2AAE
Negative weight calculated
2AAF
Weight not valid for mail type
2AB0
Weighing error (unstable - maximum number of samples exceeded)
2AB1
Weighing error (no tare achieved - maximum number of samples exceeded)
2AB2
WOW asked to weigh without calibration (calibration required)
2AB3
Compute rezero at power up is outside +/- 50 grams
2AB4
Compute rezero is outside +/- 15 grams (standard) from last rezero
Table 4-21 Motion Control Processor (MCP) and Feeder Errors (37xx)
Error
Description
37xx
Same as MidJet Motion Control Processor (MCP) Related Error Codes (16xx).
372A
FS2 has been covered for too long. Caused by a jam or by a stream feed.
372D
Jam in sealer area. Also caused by mis-feeds or "teasing" FS1. Literal cause of error is FS1 is covered and
timeout waiting for Lead Edge of FS2
37B5
Requested Operation cannot be performed in the current state.
37B6
Feeder Hardware Not Detected. May also occur if UIC times out waiting for a Start or Stop response from the
Feeder MCP.
37B7
The Requested Operation is invalid
37B8
The Feeder has not enumerated in a timely fashion.
37B9
The firmware update has failed.
37BA
No firmware has been installed in the UIC.
37BB
The Feeder Motor Thermister is not operating properly. Indicates an error with the thermister. Check the
thermister and the feeder board.
37BC
The Feeder Motor Temperature has risen too high and the system must not run mail. Stop processing mail
and allow the Feeder Motor to cool down.