Ricoh B079 Service Manual page 772

Hide thumbs Also See for B079:
Table of Contents

Advertisement

BIT SWITCHES
System Switch 0F
No
FUNCTION
0
Country/area code for
to
functional settings (Hex)
7
00: France
01: Germany 12: Asia
02: UK
03: Italy
04: Austria
05: Belgium 16: Australia
06: Denmark 17: New Zealand
07: Finland
08: Ireland
09: Norway
0A: Sweden 1B: Taiwan
0B: Switz.
0C: Portugal 20: Turkey
0D: Holland 21: Greece
0E: Spain
0F: Israel
10: Canada
System Switch 10 - Not used (Do not change the factory settings.)
System Switch 11
No
FUNCTION
0
TTI printing position
0: Superimposed on the page
data
1: Printed before the data
leading edge
1
TSI (G3) or CIL/TID (G4)
printing position
0: Superimposed on the page
data
1: Printed before the data
leading edge
2-6
Not used
7
Use of parallel memory
transmission with G4
transmission
0: Disabled 1: Enabled
B547
CÓPIA NÃO CONTROLADA
This country/area code determines the factory
settings of bit switches and RAM addresses.
However, it has no effect on the NCU parameter
11: USA
settings and communication parameter RAM
addresses.
13: Japan
14: Hong Kong
Cross reference
15: South Africa
NCU country code: Function 06, parameter C.C.
18: Singapore
19: Malaysia
1A: China
1C: Korea
22: Hungary
23: Czech
24: Poland
Change this bit to 1 if the TTI overprints information
that the customer considers to be important (G3
transmissions).
Change this bit to 1 if the TSI (G3) or CIL/TID (G4)
overprints information that the customer considers
to be important.
CIL: Command Information Line (Group 4)
Do not change the factory setting.
This determines whether parallel transmission can
be used with a G4 transmission or not.
Note that this bit is only effective if Parallel Memory
transmission is enabled (User Parameter 07 - bit 2).
CÓPIA NÃO CONTROLADA
COMMENTS
COMMENTS
46
SP No. 1-101-016
SP No. 1-101-018
SM