FUSING UNIT

3.15.5 THERMISTORS AND THERMOSTATS

[B]
1. Fusing unit (! 3.15.1)
2. Fusing upper and lower cover. (! 3.15.3, 3.15.4)
3. Center thermistor [A] ( x1,  x1, holder x1)
4. End thermistor [B] ( x1,  x1, holder x1)
CAUTION: The thermistors are thinly coated and extremely fragile. Handle with
care to avoid damaging them. They should be replaced every 150K.
5. Center thermostat [C] ( x2)
6. End thermostat [D] ( x2)
B079/B082
CÓPIA NÃO CONTROLADA
[A]
B004R605.WMF
[C]
3-56
CÓPIA NÃO CONTROLADA
[D]
B004R604.WMF