FUSING UNIT

3.15 FUSING UNIT
CAUTION
Allow time for the unit to cool before doing the following procedure.

3.15.1 FUSING UNIT REMOVAL

[A]
1. Open the front door, duplex unit, and right door.
2. Set screw [A] ( x 1)
3. Fusing unit release lever [B]
4. Slide out the fusing unit [C]
NOTE: A larger knob [D] is provided to make turning the hot roller easier to free
jams. The drawing of the larger knob was not updated in the remaining
illustrations.
B079/B082
CÓPIA NÃO CONTROLADA
[C]
[D]
3-52
CÓPIA NÃO CONTROLADA
[B]
B079R611.WMF
SM