Suzuki VL125 Service Manual page 197

Table of Contents

Advertisement

SIGNAL GENERATOR PEAK VOLTAGE
• Remove the luggage box. (!5-2)
NOTE:
Be sure that all couplers are connected properly and the battery
used is in fully-charged condition.
• Connect the multi circuit tester with peak volt adaptor as fol-
lows.
• Measure the signal generator peak voltage between White and
Green lead wires at the ignitor coupler.
Bl/B (+ Probe) – Green (- Probe)
" 09900-25008: Multi circuit tester set
' Tester knob indication: Voltage (%)
&
When using the multi circuit tester and peak volt adap-
tor, follow the instruction manual.
• Shift the transmission into the neutral and turn ignition switch
"ON".
• Crank the engine a few seconds with the starter motor by de-
pressing starter button and check the signal generator peak
voltage.
• Repeat the above test procedure a few times and measure
the highest peak voltage.
# Signal generator peak voltage:
If the peak voltage is lower than the standard range, check the
peak voltage at the signal generator lead wire coupler.
• Remove the luggage box. (!5-2)
• Disconnect the signal generator lead wire coupler and con-
nect the multi circuit tester with the peak volt adaptor.
Blue (+ Probe) – Green (- Probe)
• Measure the signal generator peak voltage at the signal gen-
erator lead wire coupler.
' Tester knob indication: Voltage (%
# Signal generator peak voltage:
If the peak voltage is lower than the standard range, check each
coupler at both ends of the circuit or replace the signal genera-
tor and inspect it again.
More than 4.5 V (Bl/B – Green)
%
%
% )
%
More than 4.5 V (Blue – Green)
ELECTRICAL SYSTEM 6-21
Ignitor
Signal
coupler
generator
coupler
Signal
generator
Signal
generator
coupler
Signal
generator
Peak
volt
adaptor
Peak
volt
adaptor

Hide quick links: