Segment 2
1 =
On: enables the LED extinguish feature
2 =
On: enables the require code for bypassing feature
3 =
On: enables the zone bypassed sounder alert feature
4 =
On: enables the AC power/low battery sounder alert feature
5 =
On: enables bypass toggle
6 =
On: enables silent auto arm
7 =
On: enables the automatic instant feature (of entry/exit zones)
8 =
On: enables final set door
Segment 3
1 =
On: enables opening and closing reports
2 =
On: enables zone bypass reporting
3 =
On: enables zone restore reporting
4 =
On: enables zone trouble reporting
5 =
On: enables zone tamper reporting
6 =
On: enables the cancel reporting
7 =
On: enables the recent closing report
8 =
On: enables the exit error report
Segment 4
1 =
On: enables late to close / early to open reporting
2 =
On: enables auto arm in STAY mode
3 =
On: enables instant NIGHT mode (applies to NX-1208E / NX-1248E: no toggle)
4 =
On: tamper when sensor lost if armed
5 =
On: enables instant STAY mode (toggle)
6 =
On: arming allowed with tamper memory / communication failure/ expander
trouble
7 =
On: arming allowed with battery trouble
8 =
On: keyswitch zone arms in STAY mode
Segment 5
1 =
On: Disables auto-bypassing of force armable zones at the end of the exit
delay
2 =
Reserved
3 =
Reserved
4 =
Reserved
5 =
Reserved
6 =
Reserved
7 =
Reserved
8 =
Reserved

Entry/Exit timers

LOCATION 24 - ENTRY / EXIT TIMERS (6 segments, numerical data)
Location 24 is used to program the entry/exit times. There are 2 separate entry/exit times.
Segment 1
Entry time 1
This is the entry time that will be used when a delay 1 zone
type initiates an entry delay.
Valid entries are 10-255 seconds.