Location
Term
2.6.2.2.4
Manual Dialer Test
2.6.2.3
Clock
2.6.2.3.1
Use Int.Crystal for Clock
2.6.2.3.2
Lost Clock Indication
2.6.2.3.3
Summer/Winter Time
2.6.2.4.1
Steady Siren (Fire)
2.6.2.4.2
User Code Resets Tamper
Memory
2.6.2.4.3
Use GSM If Line Trouble
2.6.2.4.4
First Alarm Logic
2.6.2.4.5
Log Protection
2.6.2.4.6
KP Shutdown Mode
2.6.2.4.7
Silent Exit Always
2.7
Arm Schedules
Definition
A menu option that includes a dialer test in the user's
manual test. A manual test call is made to the central
station and the corresponding signal is transmitted.
A menu entry that groups options that configure the clock.
A menu option that provides an accurate clock in situations
where different mains frequencies are used: 50 Hz or 60 Hz
are possible selections.
A menu option that enables the service message 'Panel
Loss of time'.
A menu option that allows automatic switching of summer
and winter time.
A menu option that sets the type of siren activated when a
fire alarm occurs. This can be either yelping or temporal.
A menu option that allows a user to reset the system after a
tamper alarm. If this option is disabled, an installer must
reset the system each time a tamper occurs. The user
should identify the cause of the alarm before arming the
system and contact the installer if necessary.
A menu option that specifies the backup phone number
over GSM. This phone number is used when the on-board
dialer fails.
A menu option that enables first alarm logic. This feature
affects the way multiple alarms are displayed on a keypad.
If this option is enabled and multiple alarms occur during an
armed cycle, the keypad will display the first tripped zone
only before disarming. After disarming, the first zone tripped
will be the one that says "Alarm Memory" with the "Alarm"
message flashing.
A menu option that prevents a single, non-zone reportable
event to fill up the event memory. The event will only be
logged for a maximum of 3 times between closings or code
entry.
A menu option that causes the keypad to display a "Please
Enter Your Code" prompt, power-on icon and "NOT OK to
arm" icon only, hiding the system status.
Note: The keypad can be programmed to display the date
and time instead of the "Please Enter Your Code"
message. This feature can be enabled or disabled
by selecting Installer menu>This Keypad>Keypad
Features>Advanced Options>KP Shutdown shows
Clock menu option.
A menu option that prevents the exit time buzzer activating
whenever the system is armed or during the re-exit time.
Setting this option also doubles the exit delay (for example,
if it is set to 30 seconds it changes to 60 seconds).
A menu entry that groups scheduling options. These
options configure the schedules used by the control panel
for auto arming.