GE NX-10 Installer Manual page 117

Hide thumbs Also See for NX-10:
Table of Contents

Advertisement

LOCATION 111 - CONFIGURATION GROUP 1 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Segment 1
1 =
Fire (turn on if this is a fire zone)
2 =
24 hour (turn on for non-fire 24 hour zones)
3 =
Keyswitch zone (normally open switch)
4 =
Follower (turn on for burglary zones that are Instant during non-entry times)
5 =
Delay 1 zone (follows timer 1 Entry and Exit times)
Delay 2 zone (follows timer 2 Entry and Exit times)
6 =
7 =
Interior (turn on if this zone should Automatically Bypass or Bypass for Stay
Arming)
8 =
Local only (turn on if this zone should not be reported)
Remark: for a maintained keyswitch (ON/OFF), program both "keyswitch"
and "local"
Segment 2
1 =
On: if configuration group will beep the keypad for alarm
On: if configuration group will sound the yelping siren for alarm
2 =
On: if configuration group will sound the steady siren for alarm
3 =
On: if configuration group will chime
4 =
5 =
On: if configuration group can be bypassed
6 =
On: if configuration group is included in the group shunt
7 =
On: if configuration group is force armable
On: if configuration group is entry guard
8 =
Segment 3
On: enables Fast Loop Response. (50mS) - Off= 500mS
1 =
2 =
On: enables Double End Of Line Tamper zone. (Mainly used for tamper on
wireless zones)
On: enables Trouble Reporting zone. (Day zone and Fire zones)
3 =
On: if configuration group is a Cross Zone
4 =
5 =
On: enables Dialer Delay zone. (See location 40)
6 =
On: if configuration group will use swinger shutdown. (See location 38)
7 =
On: enables Restore reporting
8 =
On: enables Listen-In. (See location 40)
Segment 4
1 =
On: enables zone activity monitor
2 =
On: enables end of line resistor defeat on non-fire/non-keyswitch zones
3 =
On : enables zone to act as request to exit input / disables for alarm
activation
4 =
On: enables zone to act as access entry point (Door Shunt) (*)
5 =
Reserved
6 =
Reserved
7 =
Reserved
8 =
Reserved
Segment 5
1-8
Reserved
(*) Note:
Refer to NX-17xx door control installer manual. Do not enable this segment unless
configured with Door Control.
LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code that is sent for a Contact ID or SIA report. The desired event
code should be chosen from the Table 38 or Table 39 in Appendix 1. The zone ID will be the zone
that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain
the alarm report code for the Robofon format (value 00-99).
NX-10 Installers manual
117

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents