The control panel includes up to 2 programmable on-board auxiliary outputs. To program on-board
outputs, select Installer Menu>Control Panel>Outputs.

Configuring an output

You can change the characteristics of each output. You must specify the events and/or partitions that
activate an output and the length of time for which the output is activated. The events are grouped in
the programming tree. A full list of all possible selectable events can be found in the Table 12,
Control panel output events. The following example configures output 1 to activate for 15 minutes
when a burglary alarm occurs.
Navigate with the
1.
press OK.
Scroll to Event>Alarms>Burglary Alarm and press OK.
2.
The keypad beeps once to confirm the change and returns to Alarms.
3.
Scroll to Time Unit>Minutes and press OK.
4.
The keypad beeps once to confirm the change and returns to Time Unit.
5.
Scroll to Time and press OK.
6.
Select 15 min. and press OK to accept the changes.
7.
The keypad beeps once to confirm the change and returns to Time.
8.
Table 12. Control panel output events
Data
Event
0
Burglary alarm
1
Fire alarm
2
24 hour alarm
3
Trouble alarm
4
Tamper alarm
5
Yelping siren
6
Steady siren
7
Any siren
8
Any bypass
9
AC fail
10
Low battery
11
Duress
12
Aux 1 keypad (fire alarm)
13
Aux 2 keypad (medical alarm)
14
Panic keypad
15
Keypad tamper
16
Automatic test
17
Alarm memory (solid)
18
Entry
19
Exit
20
Entry or exit
21
Armed state
22
Disarmed state
23
Ready
24
Not ready
keys to Control Panel>Outputs>Prog Outputs>Output 1 and
Data
Event
30
Open period
31
Closed period
32
Listen-in
33
Line seizure
34
Reserved
35
Fail to communicate
36
Telephone line fault
37
Program mode
38
Download in process
39
Reserved
40
Short circuit (overcurrent on 12 V DC)
41
Box tamper
42
Siren tamper
43
Any open
44
Any short
45
Any fault (open/short on non-fire zone)
46
Any alarm
47
Audible keypad
48
Code entry (see note below)
49
Keyfob function 1
50
Keyfob function 2
51
Always ON
52
Autoarm warning time
53
Any siren when in away mode
54
Progress of entry/exit (follows keypad
buzzer)
NX-10 Installers manual