Term
Attributes
Code Stops Timer
Del. RF Device
Del. RF Keypad
Del. RF Sensor
Del. RF Sir/IO
Door/Window
Enabled
Event
External Contact
Fire Supervision
Fire Window
Global Siren
House Code
I/O Output User Auth.
Inputs
Definition
seconds in order to improve the siren's battery life.
A menu entry that groups additional configuration options for IO modules.
A menu option that specifies the way entering code by the user affects the way
the output is timed. If set to Yes, the output should be reset if a code is entered
while it is being timed. When set to No, the output stays timed (not reset) after
a code is entered.
Note: Do not set up this option for system status events (such as "Ready to
Arm", "Not Ready to Arm", "Armed", "Disarmed") because once the output is
triggered it will not reset to reflect current status unless the user code is
entered.
A menu entry that groups entries related to deleting RF devices from the
system.
A menu entry that allows to delete the selected RF keypad.
A menu entry that allows to delete the selected RF sensor (zone).
A menu entry that allows to delete the selected RF siren or IO module.
A RF Receiver menu option that configures door/window settings on an RF
receiver. It includes the use of internal reed and additional external contact of
the door/windows transmitters.
A menu entry that enables/disables the selected sensor.
Selects the event that will trigger the output. See Table 18 for the specific
events that can be selected.
A menu option on an RF door/window sensor that enables an additional
external contact. When the external contact is triggered, an alarm is generated
on the same zone number as the door/window sensor (reed contact) itself.
A menu option that specifies that the receiver uses the fire supervision timing
window.
A menu option that specifies the RF supervision to be used for RF smoke/fire
detectors. The RF smoke/fire detectors send a supervision every 64 minutes.
A menu option that specifies whether the output is triggered on events that
cannot be assigned to a partition, for example, an expander tamper. If there is
a Siren On flag on any partition, the Global Siren flag is not tested.
A menu option that sets the code used to identify a particular premises. It is
necessary in case any neighbouring premises also has an X-10 home
automation system.
More information on the X-10 home automation system can be found at
www.x-10europe.com.
When activating outputs with a user code (event 45), this option can be used to
restrict certain codes from activating certain outputs.
A menu entry that groups options relating to RF zones only.