[X]
[X ...]
The settings and events in Table 27 are transmitted in the following messages.
>123456 BA001 BA003.
>987654 YT000.
>345678 TA030.
Table 27. Example settings and events
Setting
System account code for the given destination
Partition 1 account code
Partition 3 account code
BA on zone 1
BA on zone 3
Low battery on panel
TA on zone 30
Combined events
Account codes are used to identify partitions. Events for separate accounts codes can be sent in the
same message using the syntax:
aaaaaa eennn [eennn ...][/aaaaaa eennn [eennn ...]...].
See Table 26 for a detailed syntax description.
The settings and events in Table 27 are transmitted in the following message.
>123456 BA001 BA003/987654 YT000/345678 TA030.
Reporting with partition modifiers
Partition modifiers are used to identify partitions. Events with partition modifiers are sent using the
syntax:
>aaaaaa eennn[/Rin] [eennn[/Rin] ...].
See Table 26 for a detailed syntax description.
The settings and events in Table 27 are transmitted in the following message.
> 987654 BA001/Ri1 BA003/Ri1 YT000 TA030/Ri3.
Description
X is optional
X is optional and may be repeated one or more times.
Value
987654
123456
345678
Partition 1
Partition 1
YT000