LOCATION 67 - BOX TAMPER / BOX TAMPER RESTORE COMMUNICATOR CODE, SLOW SPEED
FORMATS ONLY (4 segments, numerical data)
Location 67 contains the tens and ones digits that will be sent for a 4+2 and 3+1 format if the "Box
Tamper" feature is enabled in location 37. Segment 1 contains the tens digit of the "Box Tamper".
Segment 2 contains the ones digit of the "Box Tamper". Segment 3 contains the tens digit of the
"Box Tamper Restore". Segment 4 contains the ones digit of the "Box Tamper Restore".
For a 3+1 format, only the segment 1 resp. segment 3 digit (tens) will be sent.
LOCATION 68 - AC FAIL / AC FAIL RESTORE COMMUNICATOR CODES, SLOW SPEED FORMATS
ONLY (4 segments, numerical data)
Location 68 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if "AC Fail
Reporting" is enabled. Segment 1 contains the tens digit of the "AC Fail Reporting". Segment 2
contains the ones digit of the "AC Fail Reporting". Segment 3 contains the tens digit of the "AC Fail
Restore". Segment 4 contains the ones digit of the "AC Fail Restore".
For a 3+1 format, only the segment 1 resp. segment 3 digit (tens) will be sent.
LOCATION 69 - LOW BATTERY / LOW BATTERY RESTORE COMMUNICATOR CODES, SLOW
SPEED FORMATS ONLY (4 segments, numerical data)
Location 69 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if "Low
Battery Reporting" is enabled. Segment 1 contains the tens digit of the "Low Battery Reporting".
Segment 2 contains the ones digit of the "Low Battery Reporting". Segment 3 contains the tens digit
of the "Low Battery Restore". Segment 4 contains the ones digit of the "Low Battery Restore".
For a 3+1 format, only the segment 1 digit resp. segment 3 digit (tens) will be sent.
LOCATION 70 - AUX POWER OVERCURRENT/ AUX POWER OVERCURRENT RESTORE
COMMUNICATOR CODES, SLOW SPEED FORMATS ONLY (4 segments, numerical data)
Location 70 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if "Aux
Power Overcurrent Reporting" is enabled. Segment 1 contains the tens digit of the "Aux Power
Overcurrent Reporting". Segment 2 contains the ones digit of the "Aux Power Overcurrent
Reporting". Segment 3 contains the tens digit of the "Aux Power Overcurrent Restore". Segment 4
contains the ones digit of the "Aux Power Overcurrent Restore".
For a 3+1 format, only the segment 1 resp. segment 3 digit (tens) will be sent.
LOCATION 71 - BELL TAMPER AND BELL TAMPER RESTORE COMMUNICATOR CODES, SLOW
SPEED FORMATS ONLY (4 segments, numerical data)
Location 71 contains the tens and ones digits for a 4+2 and 3+1 format that will be sent if siren
supervision reporting is enabled. Segment 1 contains the tens digit of the "Bell Tamper Reporting".