Iwatsu Omega-Phone Adix APS Owner's Manual page 24

Telephones
Hide thumbs Also See for Omega-Phone Adix APS:
Table of Contents

Advertisement

RAM Capacity
(B1):
w/IX-CPU20 MEM-M
(B1):
w/IX-CPU20 MEM-L
Heat Dissipation
IX-100PWS
1330 BTU/hr
(max.):
IX-200PWS
3670 BTU/hr
(max.):
Environment
Storage Temperature:
-10° to 50°C/14° to 122°F
Relative Humidity (non-
condensing): 10% to 90%
Power
Nominal
Max.
IX-PWSS: 86 watts 122 watts
IX-PWSM:167 watts 250 watts
IX-PWSL:252 watts 360 watts
AC Input
AC Input Voltage Tolerance:
IX-PWSS: 108V-132V @ 120V
IX-PWSM: 90V-135V @ 110V
IX-PWSL: 108V-132V @ 120V
Frequency Tolerance:
IX-PWSS:
54 Hz-66 Hz
IX-PWSM:
47 Hz-63 Hz
IX-PWSL:
47 Hz-63 Hz
Maximum Input Current
IX-PWSS:
2.0A
IX-PWSM:
2.0A
IX-PWSL:
3.0A
Ringing Generator
Frequency:
Amplitude:
Maximum Simultaneous Ringing
(SLT):
ADIX APS GENERAL DESCRIPTION - 10
Battery Backup
4 MB
ADIX APS (IX-PWSL) power
6 MB
supplies include a battery
interface. Backup time is
dependent upon battery array,
system size and system usage.
FCC Registration
Numbers
KF: BD6MLA-21247-KF-E
MF: BD6MLA-21244-MF-E
PF: BD6MLA-21246-PF-E
IC Registration Number
577 3326 A
Facility Interface Codes
Loop Start Trunks:
Ground Start Trunks:
DID Trunks:
E&M Tie Lines: TL31M/TL32M
OPS Lines:
T1-SF:
T1-ESF:
ISDN BRI:
ISDN PRI:
Software
Abandon Call/All Call
Storage
Outgoing Trunk Groups:
Incoming Trunk Groups:
Incoming Call Ringing
20 Hz
Assignment: 16
90 Vac
Stations/Line, 32
Stations/Line if delayed
20
ringing assignment is not
programmed.
Incoming Call Delayed Ringing
Assignment:16 Stations/Line
Doorphone Ringing Assignment:
16 Stations/Doorphones
Call Pick-up Groups:
CO/ICM Hunt Groups:
02LS2
02GS2
02RV2-T
0L13C
04DU9-BN
04DU9-1KN
02IS5
04DU9-1KN
500 records
60
60
60
60

Advertisement

Table of Contents
loading

Table of Contents