Key Telephone Lamp Indications

Status
Lamp Indication
I-Use (Green)..........................................Modulation Steady (On)
CO Incoming/Call Forward ....................0.1 sec. on, 0.9 sec. off
I-Hold (Green)........................................0.5 sec. on, 0.5 sec. modulated on
System Hold/Non-Privacy ......................0.1 sec. off, 0.3 sec. modulated on
Recall, ICM Incoming, MSG .................0.7 sec. off, 0.3 sec. modulated on
DND .......................................................0.5 sec. on, 0.5 sec. modulated on
Busy........................................................Steady (On)

Station Port Requirements

Model
Description
Ports Required
IX-ATT .............. Attendant Console.......................................................2
IX-BLF ............... Busy Lamp Field.........................................................1
IX-DCKT900 ..... Digital Wireless Telephone.........................................1
or shared with
digital telephone
IX-DSS-A........... 50 DSS & 20 function keys with display ....................1
IX-DSS-A-2........ 50 DSS & 20 function keys with display ....................1
IX-DSS-B ........... 50 DSS keys................................................................1
IX-8KTS............. 8 line keys ...................................................................1
IX-8KTD ............ 8 line keys with display...............................................1
IX-12KTS-2 ....... 12 line keys (24 line keys with IX-ELK) ....................1
IX-12KTD-2....... 12 line keys (24 line keys with IX-ELK) ....................1
IX-24KTS........... 24 line keys .................................................................1
IX-24KTD .......... 24 line keys with display.............................................1
IX-VT................. Versa-Phone................................................................1
IX-DMS.............. Data Module ...............................................................1
IX-DDPH ........... Digital Doorphone ......................................................1

Time Parameters

Hold Recall Timer ..................................0 - 255 seconds
Timed Trunk Queuing ............................1 - 20 minutes
Doorphone Answer Time .......................5 - 255 seconds
VSS Recording Time..............................0 - 120 seconds
Hunting Time .........................................0 - 255 seconds
Night Mode Start Time...........................00:00 - 23:59
Auto CO Answer Start Time ..................00:00 - 23:59
MISC Relay Timer .................................10 - 255 ms
DISA-Waiting Time ...............................0 - 255 seconds