Selecting a Mounting Location

The mounting location of the AudioScience microphone can be determined through the
application of three principles:
1. All desirable seating positions should be within 14 feet (5 meters) of the microphone
capsule, with an unobstructed line of sight to the microphone capsule.
2. All undesirable noise sources should be blocked from reaching the microphone capsule
by one or both boundaries of the microphone.
3. The mounting holes of the microphone boundary must be directly under a ceiling track
to allow for mounting hardware. Additionally, to allow for easier changing of lighting
tubes or bulbs, the microphone should not be mounted where the microphone blocks
these items. If, due to acoustic concerns, a light fixture has to be "blocked" then string
the microphone cable in such a way as to allow for removal of the microphone when
light bulbs or tubes need to be changed.