Touchscreen Calibration - TANDBERG Director Installation Manual

Codec software version b5, control software version v1
Hide thumbs Also See for Director:
Table of Contents

Advertisement

Touchscreen Calibration

Once the system is installed and functioning, it is recommended that the touchscreen device
(touchpanel or Smartboard) is calibrated. First touch and hold the top left corner of the
screen for 5 seconds. This will give you a hidden setup screen. Then touch and hold the
bottom right corner of the screen for another 5 seconds.
Press and
hold
You will get the following screen.
Selecting "Calabrate System" will display a series of push-points on the touchscreen device used
to calibrate the screens. After the third pint, the system will restart and return to the Opening
Page. If it is not possible to reach this page because the calibration is too far off the screen, you
can connect direct to the Director Module and enter a simple command. To do this:
1. Connect with a "straight through" RS232 cable to the Program port on the back of the
Module.
2. Open a terminal program such as HyperTerminal or Viewport.
3. Set the baud rate settings to 115200,N,8,1.
4. Type the command CALTOUCH and <enter>.
5. Touch the crosshairs on the screen to calibrate the system.
15
15
15
15
Press and hold
for 5 seconds