Cabling; Isdn Bri; Isdn Pri/T1; Lan - TANDBERG Director Installation Manual

Codec software version b5, control software version v1
Hide thumbs Also See for Director:
Table of Contents

Advertisement

Cabling

Cables for this system are connected at the rear interface panel of the Director Application Module
(Director Module), either directly to the Codec. Connect cables to the Director Module as
required. Coil up any excess lengths of cable.
Connect the network cables that are applicable to the site. Refer to the TANDBERG 6000 User
Manual for more information concerning IP settings and other network equipment that may be
required, such as network terminating units and CSUs.
For additional information regarding the external cabling of the Director system, please refer to
the Director External Cabling Diagram.

ISDN BRI

Connect each cable (labeled 1 to 4) to the ISDN BRI sockets on the Codec. Then connect the
other end of the loom to the appropriate wall sockets. If however, the wall sockets provide an
ISDN U-interface, the ISDN lines from the Codec must first be connected to the S/T interface of
network terminating units NT1 and NT384. Then connect the U interface of the network
terminating units to the wall sockets.

ISDN PRI/T1

Connect the PRI/T1 cable to the PRI/T1 socket labeled "1" on the Codec. Connect the other end
of the cable to a Channel Service Unit (CSU). Then connect the CSU to the site's PRI/T1 line.

LAN

Connect the LAN cable from the LAN connector on the rear of the Codec to the site's LAN
network connection.
It is recommended that both the codec and control system be provided with a LAN connection.
The system will function without this connection, but is recommended for both software upgrades
and remote diagnostics. For information regarding the network settings on the codec, refer to the
TANDBERG 6000 User's Manual. The control system LAN information must be set locally.

Device Connections

Microphone

Connect the microphone cable to the XLR input of the 6000 codec. The default codec setting has
all microphone inputs enabled and the gain set to +3dB. Adjustments to the audio settings may be
done in the "Touchscreen Tools" (discussed later in this document), or with the remote control.

Touchpanel

If a touchpanel was sold with the system, attach the male DB25 pin end of the cable to the
Director Module, and connect the RJ modular ends to the touchpanel. Power for the touchpanel is