SMC Networks SMC6624M Management Manual page 257

Tigerstack ii 10/100 stackable fast ethernet switch
Hide thumbs Also See for SMC6624M:
Table of Contents

Advertisement

Blue
Server
Red
VLAN
4
Switch
3
Red
Server
Green
Server
Ports 1-6: Untagged
Port 7: Red VLAN Untagged
Green VLAN Tagged
Figure 9-54. Example of Tagged and Untagged VLAN Port Assignments
I
In switch X:
VLANs assigned to ports X1 - X6 can all be untagged because there is
only one VLAN assignment per port. Red VLAN traffic will go out only
the Red ports; Green VLAN traffic will go out only the Green ports,
and so on. Devices connected to these ports do not have to be 802.1Q-
compliant.
However, because both the Red VLAN and the Green VLAN are
assigned to port X7, at least one of the VLANs must be tagged for this
port.
In switch Y:
I
VLANs assigned to ports Y1 - Y4 can all be untagged because there is
only one VLAN assignment per port. Devices connected to these ports
do not have to be 802.1Q-compliant.
Because both the Red VLAN and the Green VLAN are assigned to port
Y5, at least one of the VLANs must be tagged for this port.
I
In both switches: The ports on the link between the two switches must be
configured the same. As shown in figure 9-54 (above), the Red VLAN must
be untagged on port X7 and Y5 and the Green VLAN must be tagged on
port X7 and Y5, or vice-versa.
Port-Based Virtual LANs (Static VLANs)
Blue
VLAN
Red VLAN: Untagged
5
6
Green VLAN: Tagged
7
"X"
1
2
Green
VLAN
Ports 1-4: Untagged
Port 5: Red VLAN Untagged
Configuring Advanced Features
White
White
VLAN
Server
4
3
Switch
5
"Y"
1
2
Red
Green
VLAN
VLAN
Green VLAN Tagged
9-67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6624fmst6624glsc6624gssc6624gt6624m6624s

Table of Contents