2.2

System Level Environmental Limits

The following table defines the system level operating and non-operating environmental limits.
Parameter
Temperature
Operating
Shipping
Altitude
Operating
Humidity
Shipping
Shock
Operating
Unpackaged
Packaged
Vibration
Unpackaged
Packaged
AC-DC
Voltage
Frequency
Source Interrupt
Surge Non-
operating and
operating
Line to earth Only
ESD
Air Discharged
Contact
Discharge
Acoustics
Sound Power
Measured
Power in Watts
Servers/Rack
Mount BA
®
See the Intel
S2600GZGL Product Family Power Budget and Thermal Configuration Tool for system
configuration requirements and limitations.
6
®
Intel
Server System R1000GZ/GL Product Family TPS

Table 2. System Environmental Limits Summary

Limits
ASHRAE Class A2 – Continuous Operation. 10º C to 35º C (50º F to 95º F) with the maximum
rate of change not to exceed 10°C per hour
ASHRAE Class A3 – Includes operation up to 40C for up to 900 hrs per year.
ASHRAE Class A4 – Includes operation up to 45C for up to 90 hrs per year.
-40º C to 70º C (-40º F to 158º F)
Support operation up to 3050m with ASHRAE class deratings.
50% to 90%, non-condensing with a maximum wet bulb of 28° C (at temperatures from 25° C
to 35° C)
Half sine, 2g, 11 mSec
Trapezoidal, 25 g, velocity change is based on packaged weight
Product Weight: ≥ 40 to < 80
Non-palletized Free Fall Height = 18 inches
Palletized (single product) Free Fall Height = NA
5 Hz to 500 Hz
2.20 g RMS random
5 Hz to 500 Hz
1.09 g RMS random
90 Hz to 132 V and 180 V to 264 V
47 Hz to 63 Hz
No loss of data for power line drop-out of 12 mSec
Unidirectional
AC Leads
2.0 kV
I/O Leads
1.0 kV
DC Leads
0.5 kV
12.0 kV
8.0 kV
<300 W
≥300 W
7.0
7.0
Revision 1.1
≥600 W
≥1000 W
7.0
7.0

Advertisement