By default, each error event scrolls automatically so that the entire error message can be read without pressing
either the left or right scroll buttons. To stop auto scrolling, cursor has to be brought under the event message
and the right button has to be pressed. Then the screen freezes. To start scrolling again right button has to be
pressed when the cursor is under the event message. So, when the cursor is under event message, the right
button decides whether to scroll or freeze the display of event message on the screen. When the cursor is
under the event message, pressing enter button displays the failing FRU (if any) in an easily human readable
format for that error event. Pressing enter button alternatively switches the display between error message and
the failing FRU (if any) information of that error message alternatively. If there is no FRU device associated
with that error, then enter button has no effect when the cursor is under the error message. Left button moves
the cursor under the previous token or menu item, i.e "->".
8.4

View Menu

The following screen is displayed when "View" item is selected in the main menu.
Based on the user's selection, details of the specific item will be displayed. The following sub sections explain
the above menu items in detail.
8.4.1

System FW Version (SysFwVer)

Selection of the "SysFwVer" item in the "View" menu displays the current firmware versions of the system as
shown below:
This is a leaf node and there is no further traversal below this menu. User can only go to the previous screen
by selecting the item, "^". This applies to all the items of "View" menu.
8.4.2

System Information (SysInfo)

Selection of "SysInfo" item in the "View" menu displays the Server's name, model, GUID, asset tag and custom
string. It is also a leaf node like above menu. The blanks in the following display will be replaced by their
values.
Each of the above fields is explained below:
a. Server Name: Value specified in the product name in the product FRU information in the main board BMC
FRU.
b. Server Model: Value specified in the product part number in the product FRU information in the main board
BMC FRU.
c. Asset tag: Value specified in the product asset tag in the product FRU information in the main board BMC
FRU.
d. Server GUID: System UUID stored by BIOS.
e. Custom String: Custom string placed by the OEM\end user.
®
Intel
Server System R1000GZ/GL Product Family TPS
^ | SysFwVer | SysInfo | BMC IP Conf |
RMM4 IP Config | Power | Last PC

Figure 30. View Menu

^ | BIOS = xx.xx | BMC = xx.xx | ME =
xx.xx | FRUSDR = xx.xx

Figure 31. System Firmware Versions Menu

^ | Server Name: ....... | Server Model:
..... | Asset Tag: ..... | Server GUID: ....
| Custom String: ........

Figure 32. System Information menu

Revision 1.1
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

R1000gl

Table of Contents