Parameter
Operating Temperature
Non-Operating
Temperature
Non-Operating Humidity
Acoustic noise
Shock, operating
Shock, unpackaged
Shock, packaged
Vibration, unpackaged
Shock, operating
ESD
System Cooling
Requirement in BTU/Hr
9.2

Serviceability and Availability

The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform
the listed system maintenance procedures, after diagnosis of the system and having identified
the failed component.
Remove cover
Remove and replace hard disk drive
Remove and replace power supply module
Remove and replace system fan
Remove and replace control panel module
Remove and replace baseboard
Revision 2.2

Table 27. System Environmental Limits Summary

+10 C to +35 C with the maximum rate of change not to exceed 10 C per hour
-40 C to +70 C
90%, non-condensing at 35 C
Sound power: 7.0 BA in an idle state at typical office ambient temperature. (23
+/- 2 degrees C)
Half sine, 2 g peak, 11 mSec
Trapezoidal, 25 g, velocity change 136 inches/sec (≧40 lbs to > 80 lbs)
Non-palletized free fall in height 24 inches (≧40 lbs to > 80 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
Half sine, 2 g peak, 11 mSec
+/-15kV except I/O port +/-8KV per Intel Environmental test specification
2550 BTU/hour
Activity
Intel order number D71005-005
Environmental and Regulatory Specifications
Limits
Time Estimate
1 min
5 min
1 min
7 min
2 min
15 min
31