H. IPI Battery Tray/Battery Installation
The IntelliFire Plus
system has a battery backup option.
TM
Battery longevity and performance will be affected by the
service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency such as an outage.
The removable battery tray is located in the lower left
corner of the appliance next to the lower glass clip. Remove
batteries from tray before sliding tray back into appliance.
See Figure 2.3.
A notch on the right side of the tray engages the tray with the
appliance. See Figure 2.4. To remove the tray, rotate the
left side of the tray outward and pull to the left to disengage
the notch. Place the batteries in the tray and return it to the
closed position with the notch engaged in the appliance.
Figure 2.3 Location of Battery Tray
Figure 2.4 Pull Left Side of Tray Out and Disengage Notch
Figure 2.5 Battery Tray Pulled Out
NOTCH
Heat & Glo • Escape-I35FB, Escape-I30FB • 2201-900 Rev. K • 5/11
I. Control Module Operation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.6.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
remote. The unit should be in the OFF position during
installation, service, battery installation, fuel conversion,
and in the event that the control goes into LOCK-OUT
mode as a result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI fl ame setting, with no adjustment in fl ame
output. This mode of operation is primarily used for
initial installation or power outage operation with battery
backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300).
2. If using a wired wall switch with the module in REMOTE
mode, the fl ame output can be adjusted with the HI/LO
selector switch on the module. See Figure 2.6. Note
that the fl ame HI/LO selector switch will become inactive
once an optional remote control (RC200/RC300) is
programmed to the control module. Note that the control
module will always ignite the fi replace on HI and remain
so for the initial 10 seconds of operation. If the HI/LO
is switched to the LO position, the fl ame output will
automatically drop to the lowest setting after the fl ame
has been established for 10 sec. After this 10 second
period, the fl ame can be adjusted from HI to LO with
the switch.
3. The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the RC300
remote.
4. If you intend to use both an optional wired wall switch
and the RC300 remote control to operate your fi replace,
the wall switch will override any commands given by
the remote.
STATUS INDICATOR LED
FLAME HI/LO SWITCH
Figure 2.6 Control Module
SELECTOR
SWITCH
NG/LP SETTING
9