Heat & Glo ESCAPE-42DV Owner's Manual

Hearth and home technologies gas fireplace owner's installation and operation manual
Hide thumbs Also See for ESCAPE-42DV:
Table of Contents

Advertisement

Para obtener un ejemplar en Español de este
Manual del propietario, visite www.heatnglo.com.
Model:
Escape-42DV
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo ESCAPE-42DV

  • Page 1 • installation must be performed by a licensed plumber or gas fi tter; See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 du propriétaire, visitez www.heatnglo.com. Owner’s Manual Installation and Operation •...
  • Page 2 (Po. Col. d’eau) IN CANADA Mode l: 0-0000 FT . 0000-0000FT . (Modele): 00,000 00,000 00,000 00,000 Serial #XXXXX #XXXXX (Serie): Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Model Number MADE IN US A Serial Number XXXXXXXX XXXXXXXX...
  • Page 3: Table Of Contents

    E. Contact Information ......57 = Contains updated information. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 4: Listing And Code Approvals

    35,000 with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. 31,500 33,000 29,700 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 6: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Inspect appliance and components for damage.
  • Page 7: Inspect Firebox

    • Cracks that penetrate entirely through the firebrick material. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 8: Framing And Clearances

    FROM OPENING ON BOTH SIDES Inches 57-1/2 91-1/2 64-3/4 45-3/4 Millimeters 1461 2325 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Fire Risk Provide adequate clearance: • Around air openings • To combustibles • For service access Locate appliance away from traffi...
  • Page 9: Constructing The Appliance Chase

    Ceiling Floor (Width) 57-1/2 1461 1092 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Fire Risk. Odor Risk. • Install appliance on hard metal or wood surfaces extending full width and depth of appliance. • Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.
  • Page 10: Mantel Projections

    COMBUSTIBLE 1 INCH THICK ALLOWED FLOOR OR PLATFORM UNDER THE OPENING Figure 3.6 Fireplace raised a minimum of 3 inches away from combustible surface. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 4 INCH MINIMUM UNLIMITED NON-COMBUSTIBLE MATERIAL (Acceptable on both sides of opening.)
  • Page 11: Termination Locations

    Figure 4.2 Minimum height from roof to lowest discharge Figure 4.2 specifi es minimum vent heights for various pitched roofs. Termination Figure 4.3 Multiple Vertical Termination Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 HORIZONTAL OVERHANG 2 FT. 20 INCHES MIN.
  • Page 12 Heat & Glo assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 (See Note 2) Electrical Service...
  • Page 13: Vent Information And Diagrams

    4. Vertical terminations are measured to bottom of termi- nation cap. 5. Horizontal pipe installed level with no rise. Figure 5.2 DVP Pipe Effective Length Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Vertical 8-1/2 in. Horizontal...
  • Page 14: Vent Diagrams

    Note: Must have a 24 inches minimum vertical vent before attaching any elbow to the unit. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Minimum 2 ft 610 mm 7 in*...
  • Page 15 2 ft 3 ft 4 ft 5 ft 6 ft 7 ft 10 ft t max Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 610 mm 7 in 178 mm 914 mm 2 ft 610 mm 1.2 m 4 ft 1.2 m...
  • Page 16 Note: Must have a 24 inches minimum vertical vent before attaching any elbow to the unit. Figure 5.7 RESTRICTOR Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 = 50 ft. Max. (15.2 m) = 3 ft. Min. (914mm) FLUE FLUE RESTRICTOR...
  • Page 17 3 ft 4 ft 5 ft 6 ft 7 ft 10 ft INSTALLED HORIZONTALLY Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 610 mm 7 in 914 mm 2 ft 1.2 m 4 ft 1.5 m 8 ft 1.8 m...
  • Page 18: Vent Clearances And Framing

    1 in. SIDE AND HEAT SHIELD Figure 6.3 Exterior Wall Hole Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 10 in. 12 in. 73 -1/8 in. 72 -1/8 in. * Shows center of vent framing hole for top venting. The center of the hole is one (1) inch (25.4 mm) above the...
  • Page 19: Vertical Penetration Framing

    BEND TABS IN AROUND PIPE ATTIC SHIELD INSTALLED BELOW CEILING Figure 6.5 Installing the Attic Shield Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 ATTIC ABOVE 10 IN. (254 MM) 10 IN. (254 MM) HOLE SHOULD MEASURE 10 IN.
  • Page 20: Appliance Preparation

    • Do NOT notch into the framing around the appliance spacers. Failure to keep insulation, framing or other material away from the appliance may cause fi re. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Nailing tabs (Both sides)
  • Page 21: Installing Non-Combustible Facing Material

    • Apply a non-combustible adhesive to attach tile, stone or other non-combustible fi nishing materials per manufacturer’s instructions. Figure 7.3 Complete Installation of Non-combustible Facing Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 NON-COMBUSTIBLE ZONE 60 in.
  • Page 22: Installing Vent Pipe

    Use screws no longer than 1 inch. If predrilling screw holes, do NOT penetrate inner pipe. High Temperature Silicone Sealant Figure 8.1 Lances Figure 8.2 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Commercial, Multi-family (multi-level exceeding two stories), or High-rise Applications only Figure 8.3...
  • Page 23 Cut from this end Figure 8.5 Figure 8.6 Slip Section Pilot Holes Figure 8.7 Screws into Slip Section Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 (outer) Cut from this end (inner) Pilot hole...
  • Page 24: Disassembly Of Vent Sections

    Improper support may allow vent to sag or separate. Figure 8.8 Securing Vertical Pipe Sections Figure 8.9 Securing Horizontal Pipe Sections Figure 8.10 Rotate Seams for Disassembly Figure 8.11 Align and Disassemble Vent Sections Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 25: Installing Heat Shield And Horizontal Termination Cap

    DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Burn Risk • Local codes may require installation of a cap shield to prevent anything or anyone from touching the hot cap.
  • Page 26: Installing Roof Flashing And

    fl ue of the pipe (see Figure 8.14). VERTICAL WALL ROOF PITCH IS X/ 12 H (Min.) Ft. Figure 8.14 Figure 8.15 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 TERMINATION CAP (1 of 3) CAULK CAULK STORM COLLAR SCREWS...
  • Page 27 fl ashing. Caulk around the top of the storm collar (see Figure 8.14). Figure 8.16 Assembling the Storm Collar Figure 8.17 Assembling the Storm Collar Around the Pipe Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 28: Gas Information

    Propane 11.0 inches w.c. 14.0 inches w.c. 9.2 inches w.c. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 29 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 30: Electrical Information

    Use battery pack to operate appliance only in a power failure situation. Battery polarity must be correct or module damage will occur. Optional Accessories Requirements Wiring for optional accessories should be done now to avoid reconstruction. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 CAUTION CAUTION...
  • Page 31 ORANGE PLUG BLACK BLACK GROUND PIGTAIL GREEN CONNECTION NEUTRAL ON/OFF ROCKER SWITCH GREEN Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 YELLOW (HNG) WHITE (HTL) REAR VIEW GREEN FRONT VIEW YELLOW FACTORY CONNECTED YELLOW TOGETHER FAN THERMOSTAT...
  • Page 32 (YELLOW) (ORANGE) (BLACK) (YELLOW) FAN THEMOSTAT (BLACK) (BLACK) PLUG GROUND PIGTAIL GREEN JUNCTION BOX Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WHITE (HTL) YELLOW (H&G) REAR VIEW FRONT VIEW FACTORY CONNECTED TOGETHER PLUG-ADP CONNECTION FIREBOX BACK...
  • Page 33: Finishing

    MIN. 8 IN. MIN. 6 IN. MIN. TOP OF FIREPLACE OPENING Figure 11.3 Noncombustible Zone 10-1/2 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 4 INCH MINIMUM UNLIMITED NON-COMBUSTIBLE MATERIAL (Acceptable on both sides of opening.) WARNING Fire Risk.
  • Page 34: Finishing Materials Requirements

    • The fi nishing material must NEVER pass the 1/2 inch metal edge around the opening and overhang into the glass opening. Figure 11.4 Non-combustible Finishing Material Requirements Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 7-1/2 INCH MINIMUM COMBUSTIBLE OK NON-COMBUSTIBLE...
  • Page 35: Appliance Setup

    Do NOT place Mystic Embers over lighted area of lens. Lens may melt if covered. • Save the remaining ember materials for use during fi replace servicing. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING Explosion Risk. • Follow ember placement instructions in manual.
  • Page 36: Positioning The Logs

    The four tabs on the lens frame go into the square cut out to help locate the lens. Log Assembly: LOGS-Escape-42 Figure 12.1 Figure 12.2 Figure 12.3 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 2052-925B...
  • Page 37 Place the right end of the second log on the pilot bracket. The left end of the log should rest on the base of the fi rebox (see Figure B). Figure B Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 38 fi ts into the right vertical grate tine. The back of the log rests in the small fl at spot on top of log #3. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 39 fl oor of the fi replace. Do NOT put Mystic em- bers on the burner surface around the ports. Place embers around the pilot wires to disguise the wires from view. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 40: Glass Assembly

    fl ame appearance. This should be adjusted by a qualifi ed installer at the time of installation. Shutter Settings ESCAPE42-DV ESCAPE42-DVLP Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 3/8 in. 11/16 in.
  • Page 41: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 42: Lighting Appliance

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 LIGHTING INSTRUCTIONS (IPI) 1. Turn off all electric power to the appliance.
  • Page 43: After Appliance Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 CAUTION CAUTION •...
  • Page 44: Troubleshooting

    fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or too high an inlet pressure can cause pilot fl ame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Corrective Action...
  • Page 45 1/8 in. Verify module is securely grounded to metal chassis of appliance. Verify battery voltage is at least 2.7 volts. Replace batteries if voltage is below 2.7. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Corrective Action...
  • Page 46: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 47 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Maintenance Tasks Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 48: Reference Materials

    Figure 16.1 Appliance Dimensions Ø D Inches Millimeters Location Inches Millimeters 1219 28-3/8 72-1/8 1831 2-5/8 4-1/4 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 OPTIONAL FIRESCREEN SITS OUT 1-1/2 INCHES FROM UNIT FACE 11-5/8 3-5/8 41-3/8 1052 1068 56-7/8...
  • Page 49: Vent Components Diagrams

    1- 1/2 in. (38 mm) 14 in. (356 mm) 12 in. (305 mm) DVP-WS (Wall Shield Firestop) Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 10-1/2 in. (267 mm) 4-7/8 in. ( 276 mm) 10-7/8 in. (276 mm) °...
  • Page 50 Figure 16.3 DVP vent components 8 in. Heat (203 mm) Shield Effective Length 12-1/2 in. (318 mm) Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Minimum Maximum Term Cap Effective Length Effective Length 3-1/8 in. 4-5/8 in. Trap1...
  • Page 51 (308 mm) (181 mm) 5-3/4 in. (146 mm) COOL-ADD Cap Shield 14 in. (356 mm) Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 DVP-HSM-B Extended Heat Shield 31 in. (787 mm) 24-5/8 in. 13-1/4 in. (367 mm)
  • Page 52: Log Set Assembly

    ESCAPE-42DV C. Service Parts Beginning Manufacturing Date: Mar. 2005 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08...
  • Page 53: Service Parts List

    Additional service part numbers appear on following page. COMMENTS Pre OCT 2005 Post OCT 2005 Pre OCT 2005 Post OCT 2005 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 ESCAPE-42DV Stocked at Depot PART NUMBER LOGS-ESCAPE-42 SRV750-706...
  • Page 54 2 inch Jumper Wire COMMENTS Pre OCT 2005 Post OCT 2005 Pre OCT 2005 Post OCT 2005 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 ESCAPE-42DV Beginning Manufacturing Date: Mar. 2005 Ending Manufacturing Date: ______ Stocked at Depot...
  • Page 55: Limited Lifetime Warranty

    Page 1 of 2 Wood Pellet Electric Wood Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 Components Covered Venting All Parts and Material Except as covered by Conditions, Exclusion, and Limitations listed...
  • Page 56 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. Page 2 of 2 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 4021-645A 09-01-08...
  • Page 57: Contact Information

    • Read, understand and follow these instructions for safe installation and operation. Printed in U.S.A. - Copyright 2008 Heat & Glo • Escape-42DV • 2052-900 Rev. R • 10/08 • Leave this manual with party responsible for use and operation.

Table of Contents