Listing And Code Approvals; Appliance Certifi Cation; Glass Specifi Cations; Btu Specifi Cations - Heat & Glo Escape-I35FB Owner's Manual

Table of Contents

Advertisement

1

Listing and Code Approvals

A. Appliance Certifi cation
MODELS: Escape-I30FB, Escape-I30FB-LP,
Escape-I35FB, Escape-I35FB-LP
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Appliance Heaters
STANDARD: ANSI Z21.88-2009 • CSA 2.33-2009
This product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Heat & Glo gas inserts are designed for installations into
solid fuel masonry or factory built fi replaces that have been
installed in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additional
outside air source is required.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
C. BTU Specifi cations
Models
(U.S. or Canada)
(0-2000 FT)
Escape-I30FB(NG)
CANADA
(2000-4500 FT)
(0-2000 FT)
Escape-I30FB-LP
CANADA
(2000-4500 FT)
(0-2000 FT)
Escape-I35FB (NG)
CANADA
(2000-4500 FT)
(0-2000 FT)
Escape-I35FB-LP
CANADA
(2000-4500 FT)
6
Maximum
Minimum
Input
Input
BTU/h
BTU/h
US
36,000
17,000
33,250
16,750
US
36,000
19,000
31,000
15,500
US
40,000
20,000
37,000
19,250
US
38,000
19,000
35,000
17,000
Heat & Glo • Escape-I35FB, Escape-I30FB • 2201-900 Rev. K • 5/11
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifi ce size.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa-
per, plant fi bers, plastics, or other material that can ignite
and burn, whether fl ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
• A 120 VAC circuit for this product must be protected with
ground-fault circuit-interrupter protection, in compliance
Orifi ce
Size
with the applicable electrical codes, when it is installed in
(DMS)
locations such as in bathrooms or near sinks.