After Appliance Is Lit; Frequently Asked Questions - Heat & Glo Escape-I35FB Owner's Manual

Table of Contents

Advertisement

L. After Appliance is Lit
Initial Break-in Procedure
• The appliance should be run three to four hours
continuously on high.
• Turn the appliance off and allow it to completely cool.
• Remove fi xed glass assembly. See Section 12.I.
• Clean fi xed glass assembly. See Section 3.
• Replace the fi xed glass assembly and run continuously
on high an additional 9 hours.
This cures the materials used to manufacture the fi re-
place.
NOTICE! Open windows for air circulation during ap-
pliance break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
M. Frequently Asked Questions
ISSUE
Condensation on the glass
Blue fl ames
Odor from appliance
Film on the glass
Metallic noise
Is it normal to see the pilot fl ame burn
continually?
12
This is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
This is a result of normal operation and the fl ames will begin to yellow as the appliance is al-
lowed to burn for 20 to 40 minutes.
When fi rst operated, this appliance may release an odor for the fi rst several hours. This is
caused by the curing of the paint and the burning off of any oils remaining from manufacturing.
Odor may also be released from fi nishing materials and adhesives used around the appliance.
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing
process. A non-abrasive cleaner such as gas fi replace glass cleaner may be necessary. See
your dealer.
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not affect the operation or
longevity of the appliance.
In an intermittent pilot ignition system (IPI), the pilot fl ame should turn off when appliance is
turned off. Some optional control systems available with IPI models may allow pilot fl ame to
remain lit.
Heat & Glo • Escape-I35FB, Escape-I30FB • 2201-900 Rev. K • 5/11
SOLUTIONS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Escape-i30fb-lpEscape-i35fb-lpEscape-i30fb

Table of Contents