H. IPI Battery Tray/Battery Installation
The IntelliFire
Plus system has a battery backup option.
TM
Battery longevity and performance will be affected by the
service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source
in the event of an emergency such as an outage.
I. Control Module Operation
1.
The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power
inputs and will not respond to any commands from
a wall switch or remote. The unit should be in the
OFF position during installation, service, battery
installation, and in the event that the control goes
into LOCK-OUT mode as a result of an error code.
ON Position: Appliance will ignite and run
continuously in the HI flame setting, with no
adjustment in fl ame output. This mode of operation
is primarily used for initial installation or power
outage operation with battery backup.
REMOTE Position:
commands from an optional wired wall switch and/
or the wireless remote (RC300).
2.
If using a wired wall switch with the module in REMOTE
mode, the fl ame output can be adjusted with the HI/
LO selector switch on the module. See Figure 2.3.
Note that the fl ame HI/LO selector switch will become
inactive once an optional remote control (RC200/
RC300) is programmed to the control module. Note
that the control module will always ignite the fi replace
on HI and remain so for the initial 10 seconds of
operation. If the HI/LO is switched to the LO position,
the fl ame output will automatically drop to the lowest
setting after the fl ame has been established for 10 sec.
After this 10 second period, the fl ame can be adjusted
from HI to LO with the switch.
3.
The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the
remote.
4.
If you intend to use both a wired wall switch and the
RC300 remote control to operate your fi replace, the
wall switch will override any commands given by the
remote.
5. Module Reset
This module may lock-out under certain conditions.
When this occurs, the appliance will not ignite or
respond to commands. The module will go into
lock-out mode by emitting three audible beeps, then
continuously displaying a RED/GREEN error code at
its status indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for use during power
outages. See Section H.
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. AB • 3/15
Appliance will initiate
MODULE
FLAME HI/LOW
STATUS
SWITCH
INDICATOR LED
Figure 2.3 Control Module
Locate the module selector switch. (SeeFigure 2.3).
Set the module selector switch to the OFF position.
• Wait fi ve (5) minutes to allow possible accumulated gas
to clear.
Set the module selector switch to the ON or REMOTE
position.
Start the appliance.
WARNING! Risk of Explosion! DO NOT reset the mod-
ule more than one time within a fi ve minute time period.
Gas may accumulate in fi rebox. Call a qualifi ed service
technician.
Nine Hour Safety Shutdown Feature
This appliance has a safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the
remote.
J. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed service technician:
• Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
• Review proper placement of logs, ember material and/or
other decorative materials.
• Ensure plastic fi nishing strips have been removed after
use for incorporating fi nishing materials.
• Check the wiring.
• Check the air shutter adjustment.
• Ensure that there are no gas leaks.
• Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate fi replace with fi xed glass assembly removed.
SELECTOR
SWITCH
NG/LP GAS-TYPE
SELECTOR SWITCH