INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo ESCAPE-I35-F

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 2: Table Of Contents

    E. Installing Adaptor and Termination Cap ....17  = Contains updated information. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) = Contains updated information. 2347-982 Rev. C 11/14 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 4: Product Specifi C And Important Safety Information

    31,000 15,500 (2000-4500 FT) 40,000 20,000 Escape-I35-F (0-2000 FT) (NG) CANADA 37,000 19,250 (2000-4500 FT) 38,000 19,000 ESCAPE-I35LP-F (0-2000 FT) (LP) CANADA 35,000 17,000 (2000-4500 FT) Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 5: Getting Started

    Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 6: Framing And Clearances

    6-3/8 6-3/16 15-5/8 1-13/16 1-15/16 10-11/16 8-11/16 1-3/8 1-1/16 21-11/16 19-15/16 4-1/2 4-3/16 1-9/16 1-9/16 13-3/8 12-1/8 8-3/4 8-3/4 10-3/4 2-3/8 2-1/4 Figure 3.1 Appliance Dimensions Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 7 FSI-EI30, FSI-EI35 DECORATIVE FRONTS 26-7/8 17-7/8 2-1/4 36-1/2 25-7/16 7/16 FSI-EI30 30-11/16 2-3/16 38-1/2 27-7/16 7/16 FSI-EI35  Figure 3.2 Decorative Front Dimensions - FS-EI30/FS-EI35 and FSI-EI30/FSI-EI35 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 8 HALST-EI30, HALST-EI35 DECORATIVE FRONTS 31-5/8 15-9/16 5-1/8 36-9/16 25-1/2 HALST-EI30 33-5/8 17-9/16 5-1/8 38-9/16 27-1/2 HALST-EI35  Figure 3.3 Decorative Front Dimensions - CHAF-EI30/CHAF-EI35 and HALST-EI30/HALST-EI35 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 9 GAL-EI30, GAL-EI35 DECORATIVE FRONTS 32-3/16 18-3/16 2-7/8 36-11/16 25-1/2 GAL-EI30 34-3/16 20-11/16 2-7/8 38-11/16 28-7/16 27-15/16 GAL-EI35  Figure 3.4 Decorative Front Dimensions - GAL-EI30/GAL-EI35 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 10: Fireplace Size Requirements

    1/4 IN. REQUIRED ESCAPE-I30-F METAL FLOOR OF EXISTING FACTORY-BUILT FIREBOX 5 IN. 6 IN. THIS SECTION OF 12 IN. METAL FLOOR HAS BEEN REMOVED Figure 4.1-A Figure 4.1-B Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 11 **Unit depth is measured to the back of the surround to give the depth needed for installation. In addition to these dimensions, also reference Mantel and Wall Projections (Section 10.A). Figure 4.2 Fireplace Opening Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 12: Termination Location And Vent Information

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 5.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 13: Installation Preparation

    • Install gas line into fi rebox cavity. • Check local codes and gas line sizing requirements following NFPA51. See Section 9. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 14: Installing Vent Pipe And Appliance

    VENT PIPE NOTE: TO ACHIEVE OPTIMUM PERFORMANCE, INLET AIR STARTING COLLAR MINIMIZE OR AVOID BENDS IN EXHAUST VENT PIPE. STARTING COLLAR BRACKET EXHAUST STARTING COLLAR Figure 7.1 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 15: Connecting Vent Pipe

    • Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300ºF silicone on fl ue tile top. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 16: Placing, Securing And Leveling The Appliance

    Figure 7.3 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 17: Installing Adaptor And Termination Cap

    Connect both the LINK-ZC-ADPB to Class A Pipe VENT PIPE and the termination cap to the LINK-ZC-ADPB with the self tapping screws provided. Figure 7.5 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 18: Electrical Information

    WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. • Refer to Service Parts section of appliance Owner’s Manual for replacement part information. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 19: Wiring Requirements - Intellifi Re

    EMBER BULB 50W (2) LIGHT WIRE ASSEMBLY GROUND EMC FILTER UNIT NOTE: SEE FIGURE 8.2 FOR ADDITIONAL INFORMATION GROUND Figure 8.1 Intellifi re Plus Pilot Ignition (IPI) Wiring Diagram Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 20: Programming The Rc300 To The Control Module

    fi replace is hot. • Refer to the RC300 Installation Instructions included in appliance manual bag to program the RC300 to the control module. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 21: Gas Information

    4500 feet (1370 m). • If substituting for these components, please consult local codes for compliance. Check with your local gas utility to determine proper orifi ce size. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 22: Air Shutter Setting

    NOTICE: If sooting occurs, provide more air by opening the air shutter. AIR SHUTTER Figure 9.1 Air Shutter Air Shutter Settings ESCAPE-I30-F 1/4 in. Full Open ESCAPE-I35-F 1/4 in. Full Open Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 23: Finishing

    For non-combustible material specifi cations refer to section 1.E. EXISTING NON-COMBUSTIBLE FACING 12 IN. MAX. 2 IN. MAX. 12 IN. MIN. 10 IN. MIN. Figure 10.1 Mantel Clearance Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 24: Appliance Setup

    • Note that the extended glass latch tabs on the glass frame are for the bottom glass latches. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 25: Remove The Shipping Materials

    WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 26: Place The Lava Rock

    PLACE LAVA ROCK IN GRAY AREA ONLY Figure 11.5 Placement of Lava Rock Figure 11.6 Placement of Embers (Escape-I30-F) EMBERS NOT ALLOWED IN PILOT AREA Figure 11.7 Placement of Embers (Escape-I35-F) Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 27: Install The Log Assembly And Glass Rock

    Log #1 (SRV2201-702): See Figure 2 for additional references. Position Log #1 as shown in Figure 3. Rest the left and right ends of Log #1 on the burner ledge. The pilot bracket will support the center of the log. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 28 Log #4 (SRV2201-705): See Figure 2 for additional details. Locate the log slot on the bottom left end of log #4. Mate the log slot with the right log pin. Rotate the right end of the log clockwise, until it contacts the grate tine. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 29 Log #6 (SRV2201-706): See Figures 2 and 4 for additional references. Place the thick end of the log on the fl at spot of Log #2. Place the thin end of the Log #6 on the fl at spot of Log #5 as shown in Figure 8. 2201-935F Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 30 Log #1 on the burner ledge. The pilot bracket will support the center of the log. Pull the left end of the log forward into position. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 31 WARNING! Risk of Explosion! DO NOT place glass rock on the burner surface. DO NOT place glass rock directly over burner ports. Improperly placed glass rock interferes with proper burner operation. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 32 Log #6 (SRV2202-706): See Figures 2 and 8 for additional references. Place the thick end of the log on the fl at spot of Log #2. Place the thin end of Log #6 on the fl at spot of Log #5 as shown in Figure 9. 2202-935E Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 33: Install Decorative Front/Surround

    For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 34: Reference Materials

    FLEX3-30: One 3 inch fl exible liner expands to 30 feet. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...
  • Page 35: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2014 Heat & Glo • Escape-I35-F, Escape-I30-F Installation Manual • 2347-980 Rev. G • 11/14...

This manual is also suitable for:

Escape-i35lp-fEscape-i30-fEscape-i30lp-f