Heat & Glo Escape-36DV Owner's Manual
Hide thumbs Also See for Escape-36DV:
Table of Contents

Advertisement

Model:
Escape-36DV
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Escape-36DV

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 2 AL TI TUDE : 0-0000 FT . 0000-0000FT . (Modele): MAX. INPU T BTUH: 00,000 00,000 MIN. INPU T BTUH: 00,000 00,000 Serial ORIFICE SIZE: #XXXXX #XXXXX XXXXXXXX (Serie): Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 3: Table Of Contents

    E. Contact Information ......58 = Contains updated information. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 4: Listing And Code Approvals

    fl ame proofed or not, or whether plastered or unplastered shall be considered combustible Heat & Glo Quality Systems materials. registered by SGS ICS Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 6: Getting Started

    Safety glasses Level 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Manometer Voltmeter Tape measure Noncorrosive leak check solution One 1/4 inch female connection (for optional fan). Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 7: Framing And Clearances

    • Clearances and Mantel Projections (Sections 3.C and 3.D) • Vent Clearances and Framing (Section 6). Inches 51-1/2 46-3/4 93-3/8 7-1/2 Millimeters 1308 1187 1676 2372 Figure 3.1 Appliance Locations Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 8: Constructing The Appliance Chase

    Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) 51-1/2 34-1/2 Inches 1168 1308 Figure 3.2 Clearances to Combustibles Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 9: Mantel Projections

    COMBUSTIBLE OF FIREPLACE COMBUSTIBLE 1 INCH THICK ALLOWED FLOOR OR PLATFORM UNDER THE OPENING MATERIAL Figure 3.6 Fireplace raised a minimum of 3 inches away from combustible surface. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 10: Termination Locations

    20 in. min. Horizontal distance between terminations 20 in. 24 in. min. Distance to perpendicular wall 18 in. 18 in. Vertical distance between terminations Figure 4.3 Multiple Vertical Termination Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 11 Figure 4.4 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 12: Vent Information And Diagrams

    45º elbows (see Figure 5.1). DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 5.2 DVP Pipe Effective Length Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 13: Vent Diagrams

    4 ft. 1219 mm 11-1/2 ft. 3505 mm = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED Figure 5.4 HORIZONTALLY Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 14 3-1/2 ft. 1067 mm 8 ft. 2438 4-1/2 ft. 1372 mm 11 ft. 3353 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Figure 5.5 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 15 Make sure the plate is fully in the groove so the restrictor cannot fall out (see Figure 5.8). FLUE RESTRICTOR FLUE RESTRICTOR 3” DIAMETER Figure 5.7 Figure 5.8 Flue Restrictor Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 16 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Note: Must have a 12 inches minimum vertical vent before attaching any elbow to the unit. Figure 5.9 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 17 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Note: Must have a 12 inches minimum vertical vent before attaching any elbow to the unit. INSTALLED HORIZONTALLY Figure 5.10 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 18: Vent Clearances And Framing

    Figure 6.3 Exterior Wall Hole 1 in. CLEARANCE BOTTOM & SIDES WALL SHIELD FIRESTOP WALL Figure 6.2 Horizontal Venting Clearances to Combustible Materials Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 19: Vertical Penetration Framing

    • Field construct additional shield height if insulation is deeper than height of attic ATTIC SHIELD INSTALLED ATTIC SHIELD INSTALLED shield. ABOVE CEILING BELOW CEILING Figure 6.5 Installing the Attic Shield Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 20: Appliance Preparation

    • Keep nailing tabs fl ush with the framing. • Secure the appliance to the framing by using nails or screws through the nailing tabs. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 21: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • Apply a non-combustible adhesive to attach tile, stone or other non-combustible fi nishing materials per manufacturer’s instructions. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 22: Installing Vent Pipe

    fi re or explosion may occur. Figure 8.2 Figure 8.3 Do not break silicone seals on slip sections. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 23 The pipe and slip section need to be secured by driving two screws through the overlapping portions of the outer fl ues using the pilot holes (see Figure 8.7). Figure 8.7 Screws into Slip Section Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 24: Disassembly Of Vent Sections

    • Do NOT allow vent to sag below connection point to appliance. Improper support may allow vent to sag or separate. Figure 8.11 Align and Disassemble Vent Sections Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 25: Installing Heat Shield And Horizontal Termination Cap

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8) DVP-TRAP2 can adjust 4 in. (5-3/8 to -9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 26: Installing Roof Flashing And

    Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Figure 8.15 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 27 Figure 8.17 Assembling the Storm Collar Around the Pipe until it rests on the roof fl ashing. Caulk around the top of the storm collar (see Figure 8.14). Figure 8.16 Assembling the Storm Collar Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 28: Gas Information

    Propane 5.0 inches 11.0 inches Minimum inlet pressure w.c. w.c. 14.0 inches 14.0 inches Maximum inlet gas pressure w.c. w.c. 3.5 inches 10.0 inches Manifold pressure w.c. w.c. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 29 Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 30: Electrical Information

    • Low voltage and 110 VAC voltage cannot be shared within the same wall box. WARNING Shock hazard. • Replace damaged wire with type 105º C rated wire. • Wire must have high temperature insulation. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 31 NOTE: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS. Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram *Note: Appliance will not operate unless properly grounded Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 32: Junction Box Installation

    • Feed the necessary length of wire through the connector. appliance through this opening into the valve • Make all necessary wire connections to the junction box/receptacle compartment. and reassemble the junction box/receptacle to the outer shell. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 33: Finishing

    fl oors in front of appliance. • An 12 inch minimum hearth extension must be constructed of non-combustible material. Figure 11.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening.) Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 34 WARNING Fire Risk. Finishing materials must not interfere with: • Operation of louvers or doors. • Access for service. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 35: Appliance Setup

    Embers to hide the pilot wires on left side of the burner. • Save the remaining ember materials for use during appliance servicing. Figure 12.1 • Replace glass fi rescreen and door front trim on the unit. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 36: Positioning The Logs

    The second log can be slightly resting on the edge of the burner. 2012-925C 10/06 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 37 The left end of the log is moved back until it almost covers the burner ports behind it. Do NOT cover the burner ports. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 38 fi ts into the second vertical tine from the left of the grate. The center of the log rests in the fl at spot on log #6. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 39 Some can be spread out on the burner surface to blend the transition. Place embers around the pilot wires to disguise the wires from view. Save the log instructions for future use. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 40: Glass Assembly

    Replace the glass door on the appliance. Pull out and latch the six glass assembly latches into the groove on the glass frame. UPPER GLASS CLIP Figure 12.13 Glass Assembly Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 41: Operating Instructions

    • Glass door MUST be in place and sealed before operating appliance. • Only use glass door certifi ed for use with appliance. • Glass replacement should be done by qualifi ed technician. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 42: Lighting Appliance

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 43: After Appliance Is Lit

    In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when continually? ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 44: Troubleshooting

    fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or too high an inlet pressure can cause pilot fl ame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 45 Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries solenoid ohms readings. if voltage is below 2.7. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 46: Maintaining And Servicing Appliance

    • Glass • Air passageways, grilles, control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 47: Replacing Light Bulb

    Be sure to push the grate all the way down to the fl oor and fi rmly back into its holder. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 48 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 49: Reference Materials

    SITS OUT 1-1/2 INCH ACCESS FROM UNIT FACE Location Inches Millimeters Location Inches Millimeters 25-3/8 3-1/2 34-1/2 50-7/8 1292 54-1/8 1376 1168 2-5/8 1-1/2 3-1/2 34-1/2 15-1/8 Figure 16.1 Appliance Dimensions Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 50: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 51 Wall Shield Firestop DVP-TRAP2 Wall Shield Firestop DVP-TRAP1 DVP90ST DVP90ST Heat Shield Heat Shield DVP-TRAPK2 DVP-TRAPK1 Horizontal Termination Cap Kit Horizontal Termination Cap Kit Figure 16.3 DVP vent components Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 52 Cap Shield DVP-TRAPFL Flashing 13-7/8 in. 9-1/2 in. (352 mm) (241 mm) 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 16.4 DVP vent components Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 53 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 16.5 DVP vent components Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 54 ESCAPE-36DV C. Service Parts Beginning Manufacturing Date: Sept. 2003 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 55: Service Parts List

    Pilot Orifi ce NG 593-528 Post 002868727 446-517 Pre 002868727 Pilot Orifi ce LP Post 002868727 593-527 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 56 060-521A Wire Plug Assembly 2005-021 2 inch Jumper Wire 2012-206 Wall Switch Wire 2095-550 Pre 002868727 2012-108 Pilot Bracket Post 002868727 385-512 Pre 002868727 Ground Strap Post 002868727 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...
  • Page 57: Limited Lifetime Warranty

    3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifi cations and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products. © 2007 Hearth & Home Technologies Inc. 060-981E 10/07 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04-08...
  • Page 58: Contact Information

    6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2008 Heat & Glo • Escape-36DV • 2012-900 • Rev. AA • 04/08...

Table of Contents