Heat & Glo Escape-36DV Owner's Manual
Hide thumbs Also See for Escape-36DV:
Table of Contents

Advertisement

Model:
Escape-36DV
Escape-36DVLP
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.

• What to do if you smell gas

- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH, in Canada.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Escape-36DV

  • Page 1: What To Do If You Smell Gas

    Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 2: Congratulations

    BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 3: Table Of Contents

    E. Hearth Extension ....... 48 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 4 D. Contact Information ......65  = Contains updated information. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 6 B. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be pro- tected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 9: User Guide

    (NOT SHOWN) SECTION 2.D. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 14.G. GRATE SECTION 14.F. MANTEL SECTION 5.D HEARTH SECTION 5.E CLEAR SPACE SECTION 2.C. Figure 2.1 General Operating Parts Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 10: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 11: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 12: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 13: Maintenance And Service

    Hold glass in place with one hand and secure glass • If bulb has been touched, wipe it clean with rubbing latches with the other hand. alcohol. • Reinstall door or decorative front. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 14 • Verify burner is properly secured and aligned with pilot or igniter. • Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 15 Replace pilot as necessary. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Figure 3.2 IPI Pilot Flame Patterns Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 16: Installer Guide

    IN CEILING JOISTS (SECTION 8.C ) OPTIONAL WALL SWITCH (SECTION 12.C) MANTEL AND MANTEL LEG (SECTION 5,13) SURROUND HEARTH EXTENSION (SECTION 5.E) GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 17: Design And Installation Considerations

    Non-corrosive leak check solution 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 18: Framing And Clearances

    • Clearances and Mantel Projections (Sections 5.C and 5.D) • Vent Clearances and Framing (Section 8). Inches 51-1/2 46-3/4 93-3/8 7-1/2 Millimeters 1308 1187 1676 2372 Figure 5.1 Appliance Locations Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 19: Constructing The Appliance Chase

    Sides of Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) 51-1/2 34-1/2 Inches 1168 1308 Figure 5.2 Clearances to Combustibles Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 20: Mantel And Wall Projections

    8 in. 6 in. 9 in. 7-1/2 in. 10 in. 9 in. 11 in. 10-1/2 in. 12 in. 12 in. Figure 5.3 Clearances to mantels or other combustibles above appliance Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 21: Hearth Extension

    COMBUSTIBLES UP TO OF FIREPLACE COMBUSTIBLE COMBUSTIBLE 1 INCH THICK ALLOWED FLOOR OR PLATFORM MATERIAL UNDER THE OPENING Figure 5.6 Fireplace raised a minimum of 3 inches away from combustible surface. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 22: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 23 • Vinyl protection kits are suggested for use with vinyl siding. Figure 6.3 Minimum Clearances for Termination Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 24: Vent Information And Diagrams

    76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 7.2 DVP Pipe Effective Length Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 25: Vent Diagrams

    4 ft. 1219 mm 11-1/2 ft. 3505 mm = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED Figure 7.4 HORIZONTALLY Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 26 1524 3-1/2 ft. 1067 mm 8 ft. 2438 4-1/2 ft. 1372 mm 11 ft. 3353 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Figure 7.5 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 27 Make sure the plate is fully in the groove so the restrictor cannot fall out (see Figure 7.8). FLUE RESTRICTOR FLUE RESTRICTOR 3” DIAMETER Figure 7.7 Figure 7.8 Flue Restrictor Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 28 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Note: Must have a 12 inches minimum vertical vent before attaching any elbow to the unit. Figure 7.9 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 29 = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Note: Must have a 12 inches minimum vertical vent before attaching any elbow to the unit. INSTALLED HORIZONTALLY Figure 7.10 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 30: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 31: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 32: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. ® Figure 8.6 Heat-Zone Knockouts Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 33: Appliance Preparation

    • Secure the appliance to the framing by using nails or screws through the nailing tabs. • Secure the appliance to the fl oor by inserting two screws through the pilot holes at the bottom of the appliance. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 34: Installing Non-Combustible Facing Material

    • Use a wet or dry towel or soft brush to remove dust or dirt from facing material. • Apply a non-combustible adhesive to attach tile, stone or other non-combustible fi nishing materials per manufacturer’s instructions. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 35: Installing Vent Pipe

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 36: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 37: Disassemble Vent Sections

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 38: Assemble And Install Storm Collar

    • Caulk around the top of the storm collar (see Figure 10.15). Figure 10.15 Figure 10.13 Assembling the Storm Collar Figure 10.14 Assembling the Storm Collar Around the Pipe Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 39: Heat Shield Requirements For Horizontal Termination

    Depth Depth 36DV 3-1/2 in. to 6 in. to 5-3/8 in. 10 in. DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 40: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 41: Electrical Information

    NOTICE: Do not use battery back up without removing refractory panels and mesh. Failure to do so may result in damage to components. Use battery back up to operate appliance only during power outage. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 42 NOTE: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS. *Note: Appliance will not operate unless properly grounded Figure 12.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 43: Junction Box Installation

    Copper ground attached GRN wire to GRN screw with inside box GRN wire NOTICE: DO NOT wire 110 VAC to wall switch. Figure 12.2. Junction Box Detail Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 44: Finishing

    See Figure 13.2. Figure 13.2 Step 3. Place the top side of splatter guard behind the left and right panel brackets and in front of the glass. See Figure 13.3. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 45: Mantel And Wall Projections

    FACING FIREPLACE MINIMUM 1/2 I NCH THICKNESS OPENING Height Above Opening Horizontal Mantel Distance 2-1/4 3-1/2 4-3/4 7-1/2 10-1/2 Figure 13.4 Clearances to Mantels or other Combustibles above Appliance Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 46: Facing Material

    • Sheetrock, wood or other combustibles must NOT be used as sheathing or facing in the non-combustible zone. • See Section 11 for proper clearances. • See Section 1 for combustible/non- combustible defi nitions. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 47: Finishing Materials Requirements

    HIGH TEMPERATURE (300º F / 149º C MIN.) TOP SEAL JOINT Figure 13.7 Non-combustible Finishing Material Requirements WARNING Fire Risk. Finishing materials must not interfere with: • Operation of louvers or doors. • Access for service. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 48: Hearth Extension

    MAY BE COMBUSTIBLE OF FIREPLACE 1 INCH THICK ALLOWED COMBUSTIBLE FLOOR OR PLATFORM UNDER THE OPENING MATERIAL Figure 13.10 Fireplace raised a minimum of 3 inches away from combustible surface. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 49: Appliance Setup

    Embers to hide the pilot wires on left side of the burner. • Save the remaining ember materials for use during appliance servicing. • Replace glass fi rescreen and door front trim on the appliance. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 50: Install The Log Assembly

    The second log can be slightly resting on the edge of the burner. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 51 fi ts onto the right tine of the grate. The left end of the log will fi t the contour of the burner between the ports. Do NOT cover the burner ports. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 52 fi ts into the second vertical tine from the left of the grate. The center of the log rests in the fl at spot on log #6. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 53 Some can be spread out on the burner surface to blend the transition. Place embers around the pilot wires to disguise the wires from view. Save the log instructions for future use. 2012-945B Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 54: Fixed Glass Assembly

    Replace the glass door on the appliance. Pull out and latch the six glass assembly latches into the groove on the glass frame. UPPER GLASS CLIP Figure 14.2 Fixed Glass Assembly Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 55: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 56 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 57: Reference Materials

    SITS OUT 1-1/2 INCH ACCESS FROM UNIT FACE Location Inches Millimeters Location Inches Millimeters 25-3/8 3-1/2 34-1/2 50-7/8 1292 54-1/8 1376 1168 2-5/8 1-1/2 3-1/2 34-1/2 15-1/8 Figure 16.1 Appliance Dimensions Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 58: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 59 (305 mm) 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 16.3 DVP vent components Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 60 Cap Shield 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.4 DVP vent components Cap Shield Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 61 (25 mm) 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 16.5 DVP vent components Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...
  • Page 62: Service Parts

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2011 Heat & Glo • Escape-36DV • 2012-900 Rev. AH • 11/11...

This manual is also suitable for:

Escape-36dvlp

Table of Contents