Model:
Escape-42DV
Important operating and
maintenance instructions
included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians super-
vised by an NFI certified professional.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during
operation and cool down.
• Keep children away.
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
• Do NOT operate with protective barriers open or
removed.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. Do
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer's instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo Escape-42DV

  • Page 1 Mobile Homes, CAN/CSA Z240MH. professionals, or technicians super- This appliance is only for use with the type(s) of gas indi- vised by an NFI certified professional. cated on the rating plate. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 2 Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes IN CANADA Serial Number Model: XXXXXXXX ALTITUDE: 0-0000 FT. 0000-0000FT. (Modele): MAX. INPUT BTUH: 00,000 00,000 MIN. INPUT BTUH: 00,000 00,000 Serial ORIFICE SIZE: #XXXXX #XXXXX XXXXXXXX (Serie): Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 3: Table Of Contents

    C. Service Parts ..........48 C. Installing Heat Shield & Termination Cap . 22 D. Warranty ........... 51 D. Installing Roof Flashing and Vertical E. Contact Information ........52 Termination Cap ......... 23 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 4: Listing And Code Approvals Section

    National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada. Heat & Glo Quality Systems registered by SGS ICS Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 5: Getting Started

    Safety glasses Level 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Manometer Voltmeter Tape measure Noncorrosive leak check solution One 1/4 inch female connection (for optional fan). Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 6: Framing And Clearances A. Selecting Appliance Location

    In addition to these framing dimensions, also reference the following sections: • Clearances and Mantel Projections (Section 3.C and 3.D) • Vent Clearances and Framing (Section 6). Figure 3.1 Framing Dimensions Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 7: Constructing The Appliance Chase

    Combustible Behind Sides of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) 52-1/2 57-1/2 Inches 1334 1461 Figure 3.2 Clearances to Combustibles Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 8: Mantel Projections

    1 INCH THICK ALLOWED FLOOR OR PLATFORM UNDER THE OPENING MATERIAL (4 inch Minimum to top surface of combustible floor or floor covering). Figure 3.6 Clearance to an exposed combustible hearth extension Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 9: Termination Locations

    OIL TERMINATION 20 IN. (MINIMUM) TO PERPENDICULAR WALL (GAS ONLY) TERMINATION 18 IN. Gas Termination Wood & Fuel Oil Termination 6 in. 20 in. Figure 4.3 Multiple Vertical Termination Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 10 Figure 4.4 Vent Termination Minimum Clearances CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 11: Vent Information And Diagrams

    8.5 inches hori- zontal run and 8.5 inches vertical run. A length of straight Figure 5.2 DVP Pipe Effective Length pipe is allowed between two 45 elbows (see Figure 5.1). Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 12: Vent Diagrams

    6.1 m After V = 6 ft, then H = (2 x V ) - 2 ft = 60 ft Maximum = 20 ft Maximum INSTALLED HORIZONTALLY Figure 5.4 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 13 2 x V 2Max must be adhered to. has no specific restrictions EXCEPT, = 2 x V and V cannot exceed 60 ft Maximum t max total total Figure 5.5 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 14 1.8 m 6 ft = 50 ft (15.2m) Max. *No specific restrictions on this value EXCEPT cannot exceed 60 ft (18.3m). ** H Max. = (V x 2) Figure 5.7 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 15 EXCEPT, after V = 6 ft, then H Max = 2 x V has no specific restrictions EXCEPT, after V = 60 ft Max. INSTALLED HORIZONTALLY Figure 5.8 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 16: Vent Clearances And Framing

    Non-Combustible Wall Penetration If the hole being penetrated is surrounded by noncombus- tible materials such as concrete, a hole with diameter one inch greater than the pipe is acceptable. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 17: Vertical Penetration Framing

    • Field construct additional shield height if insulation is deeper than height of at- ATTIC SHIELD INSTALLED ATTIC SHIELD INSTALLED tic shield. ABOVE CEILING BELOW CEILING Figure 6.4 Installing the Attic Shield Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 18: Appliance Preparation

    Failure to keep insulation, framing or other material away from the appliance may cause fire. • Secure the appliance to the framing by using nails or screws through the nailing tabs. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 19: Installing Vent Pipe

    INCORRECT CORRECT horizontal to vertical, one screw Figure 8.4 Seams minimum should be put in the outer flue at the horizontal elbow joint to prevent the elbow from rotating. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 20 If the slip section is too long, the inner and outer flues of the slip section can be cut to the desired length. Figure 8.7 Screws into Slip Section Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 21: Disassembly Of Vent Sections

    • Do NOT allow vent to sag below connection point to appliance. • Maintain specified slope (if required). Improper support may allow vent to sag or separate. Figure 8.11 Align and Disassemble Vent Sections Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 22: Installing Heat Shield & Termination Cap

    NOTE: Where required, an exterior wall flashing is the pipe section (see Figure 8.12). available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 23: Installing Roof Flashing And Vertical Termination Cap

    Explosion Risk. Inspect external vent cap regularly. • Ensure no debris blocks cap. • Combustible materials blocking cap may ignite. • Restricted air flow affects burner operation. Figure 8.14 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 24 Slide the assembled storm collar down the pipe section until it rests on the roof flashing). Caulk around the top of the storm collar (see Figure 8.14). Figure 8.15 Assembling the Storm Collar Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 25: Gas Information

    Natural Gas Propane Minimum 5.0 inches 11.0 inches Inlet Pressure w.c. w.c. Maximum Inlet 14.0 inches 14.0 inches Gas Pressure w.c. w.c. Manifold 3.5 inches 9.2 inches Pressure w.c. w.c. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 26 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fire hazard or bodily injury. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 27: Electrical Information

    Also carefully follow the “Setting Flame Height/Manifold Pressure” section of the included instructions to properly set the valve pressure. Operating instructions are also in- cluded in the WSK-MLT instructions. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 28 CONTINUOUS 110VAC SUPPLY NEUTRAL Note: Appliance will not operate unless properly grounded. * Must order PLUG-ADP separately if using the Heat-Zone. Figure 10.1 Intellifire Pilot Ignition (IPI) Wiring Diagram Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 29: Finishing

    Seal joints between the finished wall and appliance top and sides using only a 300 F minimum sealant. 4 inch Unlimited MANTEL Figure 11.2 Mantel Leg or Wall Projections (Acceptable on both sides of opening.) Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 30: Facing Finishing Options

    • Slide the two tapered tabs on bottom of each panel into material. See Figure 11.5. slots of top surround. • Metal panels are not required. • Secure panels with sheetmetal screws included in manual bag. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 31: Appliance Setup

    • Place Mystic Embers on the floor of unit. Use Mystic Embers to hide the pilot wires on left side of the burner. • Save the remaining ember materials for use during fire- place servicing. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 32: Positioning The Logs

    The four tabs on the lens frame go into the square cut out to help locate the Figure 12.2 lens. Figure 12.3 2052-925 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 33 LOG #2 (SRV569-705): Place log #2 on the right side of the burner on the floor. The log will be in front of the orange Kapton lens. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 34 The back of the log rests in the small flat spot on top of log #3. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 35 Do NOT put Mystic embers on the burner surface around the ports. Place embers around the pilot wires to disguise the wires from view. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 36: Glass Assembly

    Replace the glass door on the appliance. Pull out and latch the six glass assembly latches into the groove on the glass frame. UPPER GLASS CLIP Figure 12.13 Glass Assembly Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 37: Operating Instructions

    Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 38: Lighting Appliance

    For additional information on operating your Hearth Technologies appliance, please refer to www.Fireplaces.com. Final Inspection by 593-913C _________________________________ Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 39: After Appliance Is Lit

    Is it normal to see the pilot flame when ON/OFF is turned off unless the system is operating in cold climate mode. In a burn continually? standing pilot system the pilot will always stay on. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 40: Troubleshooting

    The sensor rod may be contaminated. Clean sensor rod with emery cloth. c. Module is not Verify that module is securely grounded to metal chassis of appliance. Verify grounded. that wire harness is firmly connected to module. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 41 Verify module is securely grounded to metal chassis of appliance. grounded. d. Module voltage Verify battery voltage is at least 2.7 volts. Replace batteries if voltage is output / Valve/Pilot below 2.7. solenoid ohms readings. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 42: Maintaining And Servicing Appliance

    • Restricted air flow affects burner operation. control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 43 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 44: Reference Materials

    ACCESS Location Inches Millimeters Location Inches Millimeters 1219 11-5/8 28-3/8 3-5/8 27-7/8 40-3/8 1026 1068 55-7/8 1419 56-7/8 1445 20-1/2 41-3/8 1052 2-5/8 4-1/4 Figure 16. 1 Appliance Dimensions Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 45: Vent Components Diagrams

    1-1/2 in. 10 in. DVP-AD1 (Adapter) 24 in. 12 in. 4 in. 5 in. 5 in. DVP-HVS (Vent Support) DVP-AS (Attic Shield) DVP-AD2 (Adapter) Figure 16.2 DVP vent components Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 46 (Shown with optional extended heat shield) DVP90ST DVP90ST Heat Shield Heat Shield DVP-TRAP2 Wall Shield Wall Shield DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Horizontal Termination Cap Kit Horizontal Termination Cap Kit Figure 16.3 DVP vent components Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 47 DVP and SL Series Components 13-7/8 in. 9-1/2 in. 11-5/8 in. 12-1/8 in. 7-1/8 in. 14 in. 5-3/4 in. DRC-RADIUS COOL-ADD Cap Shield Cap Shield Figure 16. 4 DVP vent components Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 48: Service Parts

    (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ Log Set Assembly * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 49 NGK-ESCAPE-42DV LP Conversion Kit / Module de conversion PL LPK-ESCAPE-42DV Fiber Patch Kit / La Trousse de Pièce de fibre SRV-PACK See following page for additional service part numbers. Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 50: Service Parts

    Orifice Bracket Flex Tube / Le Crochet d'orifice Fléchit le Tube 593-590A Wire Assembly / Module de fil 302-320A 12" Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle 593-592 Control Module / Module de commande Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 51: Warranty

    3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products. © 2005 Hearth & Home Technologies Inc. 060-981C 1/05 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...
  • Page 52: Contact Information

    6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2005 Heat & Glo • Escape-42DV • 2052-900 Rev. B • 5/05...